STOCKBRIDGE, Clayton County

Deer Creek MHP LLC

7051 DANIEL DR STOCKBRIDGE, GA 30281

Pool
Latest score
73
Jun 10, 2026
City
STOCKBRIDGE
County
Clayton
Inspections
1

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 10, 2026

Permit/Opening

Score: 739 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.18(11)(b) - (b) openings in the barrier shall not allow passage of a four inch diameter sphere.

15 ptsCorrected: NoRepeat: No

Observed fencing with 4 inch gap at bottom. Advised to adjust

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH above 7.8 Advised to adjust

8 - chemical feeder operational and approved

Regulation: .16(2)(b) - chemical feeder

15 ptsCorrected: NoRepeat: No

Observed chemical feeder not approved. Advised to submit documents

9 - filter: approved, maintained and operating

Regulation: 511-3-5-.08(1)(a) - (a) filters shall be listed per nsf standard 50 with the specific maximum flow rates per surface area based on media used.

15 ptsCorrected: NoRepeat: No

Observed filter not approved. Advised to submit documents

10 - pump: approved, maintained and operating

Regulation: 511-3-5-.09(1) - (1) sizing. a pump and motor shall be provided for circulation of the pool and spa water. performance of all pumps shall meet or exceed the conditions of flow required for filtering and cleaning (if applicable) the filters against the total dynamic h

15 ptsCorrected: NoRepeat: No

Observed pump not approved. Advised to submit documents.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed turnover rate cannot be verified due to new system installed. Advised to submit modification application

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Observed No Diving tile not in 4 inch lettering. Advised to correct

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed the maximum occupancy sign not available. Advised to update to correct sign

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

Observed pipes in pump room not clearly marked. Advised to identify pipes