Macon, Bibb County

Middle GA State College Rec & Wellness Center

100 COLLEGE STATION DR MACON, GA 31206-5145

Pool
Latest score
100
Dec 18, 2025
City
Macon
County
Bibb
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Dec 18, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Dec 16, 2025

Permit/Opening

Score: 873 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meters for the jet and waterfall were turned off. b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications. EHS informed the supervisor of the need for all components of the pool to be operating effectively.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

Observed some skimmers not producing a pull/current; one skimmer produced a white substance after pulling out the basket. EHS informed the supervisor of the need for the pool company to check and/or service the skimmer line.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

Observed pressure gauges on the filter and on all of the pumps that were not working; all were stuck in at a reading whether the system was turned on or off. (a) A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location. EHS informed the supervisor to have the gauges checked/replaced.

Aug 29, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 14, 2025

Permit/Opening

Score: 842 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.23(5)(g) - (g) failure to provide and maintain a barrier to inhibit unauthorized access to the outdoor facility when required.

15 ptsCorrected: NoRepeat: No

Observed the pool doors from the locker room unable to lock given that the pool is closed due to not being permitted therefore still allowing access to to the pool. (g) Failure to provide and maintain a barrier to inhibit unauthorized access to the outdoor facility when required. EHS informed the PIC of the need to have to doors fixed so that they lock in instances where the pool has to close before the complex closes.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed low alkalinity and calcium hardness levels. EHS spoke with the PIC about the levels and reviewed his test logs which showed levels were low also. PIC stated the CPO is scheduled to visit the facility tomorrow.

Jul 3, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 28, 2023

Permit/Opening

Score: 851 violation

10 - pump: approved, maintained and operating

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

Violation: The pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate. Inspector note: EHS observed the air compressor not operating at minimum capacity. Thus, there is an elevation in pH, combined chlorine, and inadequate flow of water. Corrective action: PIC has maintenance working to resolve issue.