May 27, 2026
Permit/Opening
200 BRISTOL ST PERRY, GA 31069
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
Observed calcium hardness low at 100ppm. The minimum level for calcium hardness is 150ppm. Increase calcium harness to a range of 150ppm-500ppm.
Routine
Permit/Opening
Routine
Routine
Permit/Opening
Re-inspection
Routine
Observed pH low at below 7. The allowable range of 7.2-7.8. Adjust pH to within allowable limits
Observed cyanuric acid high at over 100ppm. Lower to below 90ppm. Water will need to be replaced to reduce cyanuric. Ideal range is 30-50ppm.
Observed total alkalinity very low at 0ppm. The allowable range for total alkalinity is 60ppn-180ppm and the ideal range is 80ppm-120ppm. Raise total alkalinity to within allowable range. Total alkalinity should be in the ideal range prior to attempting to adjust pH.