Jan 20, 2026
Routine
4-2B - food-contact surfaces: cleaned & sanitized
Regulation: 511-6-1.05(6)(n) - manual and mechanical warewashing equipment, chemical sanitization-temperature, ph, concentration, hardness (p,pf)
Observed 3-compartment sink with quaternary ammonium sanitizer solution greater than 400 ppm. Employee began to add more water to dilute the solution. 511-6-1.05(6)(n) - Manual and Mechanical Warewashing Equipment, Chemical Sanitization-Temperature, pH, Concentration, Hardness (P,Pf) (n) Manual and Mechanical Warewashing Equipment, Chemical Sanitization - Temperature, pH, Concentration, and Hardness. A chemical sanitizer used in a sanitizing solution for a manual or mechanical operation at contact times specified under subsection (8)(b)3 of this Rule shall meet the requirements specified in DPH Rule 511-6-1-.07(6)(g), shall be used in accordance with the Environmental Protection Agency (EPA)-registered label use instructions P, and shall be used as follows:
- A chlorine solution shall have a minimum temperature based on the concentration and pH of the solution as listed in the following chart; P
Concentration Range Minimum Temperature
MG/L PH 10 or less oF (oC) PH 8 or less oF (oC)
25-49 120 (49) 120 (49)
50-99 100 (38) 75 (24)
100 55 (13) 55 (13)
-
An iodine solution shall have a minimum temperature of 68°F (20°C)P minimum concentration between 12.5 ppm and 25 ppm, P and pH of 5.0 or less or a pH no higher than the level for which the manufacturer specifies for the solution to be effective; P
-
A quaternary ammonium compound solution shall have a minimum temperature of 75ºF (24ºC), P have a concentration as specified in DPH Rule 511-6-1-.07(6)(g) and as indicated by the manufacturer’s use directions included in the labeling, P and be used only in water with 500 ppm hardness or less or in water having a hardness no greater than specified by the EPA-registered label use instructions; P
-
If another solution of a chemical specified under paragraphs 1 through 3 of this subsection is used, the permit holder shall demonstrate to the Health Authority that the solution achieves sanitization and the use of the solution shall be approved; P
-
If a chemical sanitizer other than chlorine, iodine, or a quaternary ammonium compound is used, it shall be applied in accordance with the EPA-registered label use instructions ;P and
-
If a chemical sanitizer is generated by a device located on-site at the food service establishment, it shall be used as specified in 1-5 of this subsection and shall be produced by a device that:
(i) complies with law as specified in sections 2(q)(1) and 12 of the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA), P
(ii) complies with 40 CFR 152.500 Requirement for Devices and 40 CFR 156.10 Labeling Requirements, P
(iii) displays the EPA device manufacturing facility registration number on the device, Pf and
(iv) is operated and maintained in accordance with manufacturer’s instructions. Pf.
- On-site chemical sanitizer generating equipment with active ingredients, such as copper, must be registered as pesticides. The active ingredient may be part of the equipment or separately added.
16B - plumbing installed; proper backflow devices
Regulation: 511-6-1.06(2)(r) - system maintained in good repair (p, c)
Observed leaking around men's restroom faucet. 511-6-1.06(2)(r) - System Maintained in Good Repair (P, C) (r) System Maintained in Good Repair. A plumbing system shall be repaired according to law; P and maintained in good repair.
15A - food and nonfood-contact surfaces cleanable, properly designed, constructed, and used
Regulation: 511-6-1.05(6)(a) - good repair & proper adjustment (c)
Observed floors in walk-in cooler in need of resealing and walk-in cooler door not properly closing. 511-6-1.05(6)(a) - Good Repair & Proper Adjustment (C) (6) Maintenance and Operation.
(a) Good Repair and Proper Adjustment.
-
Equipment shall be maintained in a state of repair and condition that meets the requirements specified under subsections (1) and (2)of this Rule.
-
Equipment components such as doors, seals, hinges, fasteners, and kick plates shall be kept intact, tight, and adjusted in accordance with manufacturer's specifications.
-
Cutting or piercing parts of can openers shall be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.
15C - nonfood-contact surfaces clean
Regulation: 511-6-1.05(7)(d) - nonfood-contact surfaces (c)
Observed rust and debris accumulation on shelving in walk-in cooler, and chipping paint and rust accumulation on reach-in cooler shelving. 511-6-1.05(7)(d) - Nonfood-Contact Surfaces (C) (d) Nonfood-Contact Surfaces. Nonfood-contact surfaces of equipment shall be cleaned at a frequency necessary to preclude accumulation of soil residues.
17C - physical facilities installed, maintained, and clean
Regulation: 511-6-1.07(2)(e) - floor covering, mats & duckboards (c)
Observed cardboard boxes being used to absorb grease and hold flour debris from mixers. 511-6-1.07(2)(e) - Floor Covering, Mats & Duckboards (C) (e) Floor Covering, Mats and Duckboards. Mats and duckboards shall be designed to be removable and easily cleanable.
17D - adequate ventilation and lighting; designated areas used
Regulation: 511-6-1.07(4)(b) - designated areas for employee activity, located to prevent contamination of food, equipment, utensils, linens, & single service articles (c)
Observed employee belongings( cup and keys) stored with single use food boxes/containers. 511-6-1.07(4)(b) - Designated Areas for Employee Activity, located to prevent contamination of food, equipment, utensils, linens, & single service articles (C) (b) Designated Areas for Employee Activity.
-
Areas designated for employees to eat, drink, use tobacco products and electronic devices shall be located so that food, equipment, linens, and single-service and single-use articles are protected from contamination.
-
Lockers or other suitable facilities shall be located in a designated room or area where contamination of food, equipment, utensils, linens and single-service and single-use articles cannot occur.