May 29, 2026

Re-inspection

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed CYA level over 90ppm at the time of this inspection. CA: Lower CYA level to 90ppm or below

May 28, 2026

Permit/Opening

Score: 813 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone non-operational at the time of this inspection. CA:Facility must replace phone and ensure it is able to dial 911.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

pH level low at the time of this inspection. CA: Ensure pH is 7.2-7.8

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed CYA level over 90ppm at the time of this inspection. CA: Lower CYA level to 90ppm or below.

Aug 6, 2025

Routine

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: Yes

Observed CYA level over 90ppm at the time of this inspection. CA: Lower CYA level to 90ppm or below.

Jun 9, 2025

Re-inspection

Score: 912 violations

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Observed facility lacking proof of daily water chemical tests at the time of this inspection. CA: Ensure pool chemistry is being tested twice daily by a trained operator.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed CYA level over 90ppm at the time of this inspection. CA: Lower CYA level to 90ppm or below.

Jun 6, 2025

Permit/Opening

Score: 764 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed a high chlorine level at the time of this inspection. CA: Ensure chlorine is 2.0-10.0ppm.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

Observed life ring rope snapping after a tug on it at the time of this inspection. CA: Facility must ensure the rope is secure

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed combined chlorine level over 0.4ppm at the time of this inspection. CA: Lower combined chlorine level to 0.4ppm or lower.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed CYA level over 90ppm at the time of this inspection. CA: Lower CYA level to 90ppm or below.

Oct 24, 2024

Routine

Score: 764 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone non-operational at the time of this inspection. CA:Facility must replace phone and ensure it is able to dial 911.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

Observed life ring missing its rope at the time of this inspection. CA: Facility must ensure that life ring has a rope attached that is either 50 feet in length or 1.5 times the maximum width of the pool.

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed combined chlorine level over 0.4ppm at the time of this inspection. CA: Lower combined chlorine level to 0.4ppm or lower.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: Yes

Observed CYA level over 90ppm at the time of this inspection. CA: Lower CYA level to 90ppm or below.

Jun 4, 2024

Permit/Opening

Score: 812 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed low chlorine levels (0.03) at the time of this inspection. CA: Chlorine levels must remain between 2.0-10.0 ppm.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: Yes

Observed High CYA levels were above ("Hi" reading) the allowed 0.90 ppm at the time of this inspection. CA: Ensure CYA level is 90ppm or less.

May 21, 2024

Permit/Opening

Score: 754 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone not working. CA: Replace phone and ensure the phone is able to dial out.

18 - combined chlorine level 0.4 ppm or less

5 ptsCorrected: NoRepeat: No

Observed combined chlorine at 1.12 ppm. CA: Ensure combined chlorine is at 0.40ppm.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed High CYA levels were above ("Hi" reading) the allowed 0.90 ppm at the time of this inspection. CA: Ensure CYA level is 90ppm or less.

30 - deck/rinse shower maintained

Regulation: 511-3-5-.18(17) - (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.

1 ptsCorrected: NoRepeat: No

Deck shower and water fountain was not operating upon beginning of inspection. CA: plumbing fixtures will need to be supplied with water and made available for guests.

Nov 30, 2023

Routine

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone not working. CA: Replace phone and ensure the phone is able to dial out.

May 15, 2023

Re-inspection

Score: 911 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed High CYA levels at the time of this inspection. CA: Ensure CYA level is 90ppm or less.