Jun 11, 2026
Complaint
1 - barrier: pool enclosed/fencing in compliance
Regulation: 511-3-5-.18(11)(a) - (11) barriers. all outdoor swimming pools and spas shall be enclosed by a barrier to prevent entry to the pool area when the pool is closed. (a) the top of the barrier shall be at least forty eight inches above grade maesured on the side of the bar
There is no barrier or gate to prevent access into the pool area through the locker rooms. Access into pool enclosure should be restricted via a locking mechanism, or other device, on the doors from the locker room into the pool enclosure. There shall not be direct access from any dwelling into the pool enclosure. For indoor pools, other means of protection, such as self-closing doors with self-latching devices, keypads, card readers or key entry devices which are approved by the appropriate administrative authority, shall be accepted so long as the degree of protection afforded is not less than the protection of an outdoor facility. This item must be corrected prior to next routine inspection or the pool will have to remain closed until corrected.
6 - proper disinfectant level
Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin
The chlorine level does not meet minimum requirement. Must be corrected prior to re-inspection. There is currently no cyanuric acid, but the pool will operate as a stabilized pool. The minimum chlorine should be maintained at 2ppm for a stabilized pool. (indoor pool should not be stabilized).
7 - ph between 7.2 and 7.8
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
The pH does not meet minimum requirement of 7.2ppm. Must be corrected prior to re-inspection. pH should be maintained between 7.2 and 7.8. Must be corrected prior to reinspection.
19 - adequate turnover rate
Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat
The required turnover is not met. The pool must turnover 165 gpm. The pressure on the filters is not high. Ensure filters and other equipment is properly maintained so turnover rate can be met. If the turnover is not met at next inspection, then filtration equipment may need to be investigated and changed as needed to ensure proper turnover rate. Once a CPO is obtained, the CPO should contact our office to discuss the turnover. The facility indicates no leak was detected. However, proper turnover for the pool must be in compliance. Further equipment modifications may be required if turnover rate can not be met. The equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. The turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less. Unless the rate is otherwise specified in subsection (b) below. This system shall be designed to give the proper turnover rate based on the manufacturer's recommended maximum pressure flow of the filter in dirty media condition of the filter, immediately prior to cleaning the filter.
36 - daily recordkeeping: water testing and self inspection performed
Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
There is no available documentation to verify a daily safety check is conducted. A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet. See CPO Guidance Docs.
36 - daily recordkeeping: water testing and self inspection performed
Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
There is no available documentation to verify the daily chemical testing is done as required. The chlorine and pH must be tested twice daily for pools. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. The water quality testing frequency shall be as indicated in the CPO guidance document.
21 - cyanuric acid level not exceeding maximum
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
The cyanuric acid level exceeds the maximum allowance of 90 ppm. Reduce CYA to get maximum effectiveness of the chlorine. Stabilizer (if used) Cyanuric acid, ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: - May reduce chlorine efficacy Too Low: - Chlorine Residual rapidly destroyed by sunlight Note: Stabilizer is not needed in indoor or brominated pools and spas. Indoor pool should not be stabilized.
32 - operator training certification available onsite and approved
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
There is no available documentation to show there is a current, certified CPO associated with the pool. The trained operator shall have a current certificate showing completion of an approved operator training course. A copy of the original certificate or documentation shall be available onsite for inspection by the Health Authority.
35 - operator facility inspections performed; written documentation
Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:
There is no available documentation onsite to verify the CPO is checking the required items per code. (see CPO guidance in email). Written documentation of the operator’s visits must be available at the pool facility. At a minimum, the written record must indicate the condition of the filtration and sanitizing equipment, deck, and safety items.
22 - signs: peak occupancy/pool/spa/signs legible and in clearview
Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou
There is no universal symbol for No Diving and the words No Diving are not in 4" letter height. These must be in compliance prior to permitting season 2028. (a) The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers
37 - other violations of the chapter
.17(2) The alkalinity exceeds the maximum requirements. Alkalinity is required to be at 60ppm minimum and 180 ppm maximum. Speak with CPO about adjusting the alkalinity in the pool, then verify the pH is within proper range.
37 - other violations of the chapter
.04(9)(d) There is chipping plaster in the pool. Repair plaster to ensure smooth surface. All surfaces that come in contact with the user shall be finished so that they do not constitute a cutting, pinching, puncturing or abrasion hazard under casual contact and intended use. All materials shall be maintained in accordance with manufacturer's instructions.
37 - other violations of the chapter
.13(2)(b) There is no documentation to verify the annual gas fired inspection is performed. An annual gas fired inspections shall be performed by a qualified professional.