Fayetteville, Fayette County

Piccadilly Holdings LLC

955 N GLYNN ST FAYETTEVILLE, GA 30214

Food
Latest score
82
Mar 25, 2026
City
Fayetteville
County
Fayette
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Mar 25, 2026

Routine

Score: 8213 violations

2-2B - proper eating, tasting, drinking, or tobacco use

Regulation: 511-6-1.03(5)(k)1&2 - eating, drinking, or using tobacco (c)

4 ptsCorrected: YesRepeat: Yes

Observed employee drinks stored in single-use containers with a lid and a straw and in non-single-use containers with a lid and a straw that were stored with and above food and food contact surfaces. COS. Moved. Code: Employee drinks shall be in single-use containers with a lid and a straw and shall be handled to prevent contamination.

2-2D - adequate handwashing facilities supplied & accessible

Regulation: 511-6-1.06(2)(o) - using a handwashing sink- operation & maintenance (pf)

4 ptsCorrected: YesRepeat: No

Observed the hand sink in the front service area being used as a dump sink. COS. Employees trained on proper sink usage. Code: A handwashing sink shall not be used for purposes other than handwashing.

4-2A - food stored covered

Regulation: 511-6-1.04(4)(c)1(iv) - packaged & unpackaged food, food stored covered(c)

4 ptsCorrected: YesRepeat: No

Observed containers of raw chicken stored uncovered in reach in cooler. COS. Lids placed. Code: Food shall be stored covered.

12A - contamination prevented during food preparation, storage, display

Regulation: 511-6-1.04(4)(q) - food storage (c)

3 ptsCorrected: YesRepeat: No

Observed containers stored directly in food product. COS. Containers moved. Code: Food shall be stored to prevent contamination.

12A - contamination prevented during food preparation, storage, display

Regulation: 511-6-1.04(4)(q) - food storage (c)

3 ptsCorrected: YesRepeat: No

Observed raw meat stored in the sanitizer side of the 3-compartment sink. COS. Removed. Code: Food shall be stored in a manner to prevent contamination.

12C - wiping cloths: properly used and stored

Regulation: 511-6-1.04(4)(m) - wiping cloths, use limitation (c)

3 ptsCorrected: NoRepeat: No

Observed sanitizer buckets stored with clean equipment. Code: Containers for chemical sanitizer shall be stored in a manner that prevents contamination of food, equipment, and single-service items.

12C - wiping cloths: properly used and stored

Regulation: 511-6-1.04(4)(m) - wiping cloths, use limitation (c)

3 ptsCorrected: NoRepeat: No

Observed wet wiping cloths stored on counters and in containers not containing sanitizer solution. Code: Wet wiping cloths shall be stored in sanitizer at the correct concentration between uses.

17C - physical facilities installed, maintained, and clean

Regulation: 511-6-1.07(5)(a),(b) - good repair, physical facilities maintained; cleaning, frequency & restrictions, cleaned often enough to keep them clean (c)

1 ptsCorrected: NoRepeat: No

Observed accumulation of debris and grease on floors and walls. Code: Facility shall be thoroughly cleaned and cleaning frequency shall be enough to prevent accumulation.

17C - physical facilities installed, maintained, and clean

Regulation: 511-6-1.07(5)(a),(b) - good repair, physical facilities maintained; cleaning, frequency & restrictions, cleaned often enough to keep them clean (c)

1 ptsCorrected: NoRepeat: No

Observed missing floor tiles and cracked floor tiles throughout facility; observed wall by back hand sink in the prep area in disrepair; observed broken and missing coving throughout the kitchen. Code: Facility shall be maintained in good repair.

17D - adequate ventilation and lighting; designated areas used

Regulation: 511-6-1.07(4)(b) - designated areas for employee activity, located to prevent contamination of food, equipment, utensils, linens, & single service articles (c)

1 ptsCorrected: YesRepeat: Yes

Observed employee belongings stored with and above food. COS. Moved. Code: Employee belongings and activities shall be done in a designated area to prevent contamination.

14B - utensils, equipment and linens: properly stored, dried, handled

Regulation: 511-6-1.05(10)(a) - equipment & utensils, air-drying required (c)

1 ptsCorrected: YesRepeat: No

Observed cups stacked while wet. COS. Unstacked and air dried. Code: Equipment and utensils shall be properly air dried prior to stacking.

15A - food and nonfood-contact surfaces cleanable, properly designed, constructed, and used

Regulation: 511-6-1.05(4)(b) - fixed equipment, spacing or sealing (c)

1 ptsCorrected: NoRepeat: No

Observed hand sinks are not properly attached to the wall. Code: Equipment exposed to splash or spillage shall be properly attached the adjoining equipment.

15C - nonfood-contact surfaces clean

Regulation: 511-6-1.05(7)(a)2,3 - equipment, food/nonfood-contact surfaces, and utensils, food-contact surfaces of cooking equipment & nonfood-contact surfaces free of accumulations (c)

1 ptsCorrected: NoRepeat: Yes

Observed accumulation of debris and grease on and in equipment such as shelving, fryers, and reach in units; observed accumulation of mold/mildew-like substance on the inside of the ice machine on the non-food contact portion. Code: Non-food contact surfaces shall be thoroughly cleaned and cleaning frequency shall be enough to prevent accumulation of debris.

Jul 3, 2025

Routine

Score: 927 violations

2-2B - proper eating, tasting, drinking, or tobacco use

Regulation: 511-6-1.03(5)(k)1&2 - eating, drinking, or using tobacco (c)

4 ptsCorrected: YesRepeat: No

Observed employee drinks stored in single-use containers with a lid and a straw and in non-single-use containers with a lid and a straw that were stored with and above food and food contact surfaces. COS. Moved. CA: Employee drinks shall be in single-use containers with a lid and a straw and shall be handled to prevent contamination.

2-2D - adequate handwashing facilities supplied & accessible

Regulation: 511-6-1.07(3)(a) - handwashing cleanser, availability (pf)

4 ptsCorrected: YesRepeat: No

Observed that the hand sink in the back by the dishpit did not have soap. COS. Soap refilled. CA: Hand cleanser shall be available at all hand sinks.

15A - food and nonfood-contact surfaces cleanable, properly designed, constructed, and used

Regulation: 511-6-1.05(6)(a) - good repair & proper adjustment (c)

1 ptsCorrected: NoRepeat: No

Observed that the gaskets on the combination cooler/freezer were in a state of disrepair. CA: Equipment shall be maintained in a state of good repair.

15C - nonfood-contact surfaces clean

Regulation: 511-6-1.05(7)(a)2,3 - equipment, food/nonfood-contact surfaces, and utensils, food-contact surfaces of cooking equipment & nonfood-contact surfaces free of accumulations (c)

1 ptsCorrected: NoRepeat: Yes

Observed accumulation of debris and grease on and in equipment; observed accumulation of mold/mildew-like substance on the inside of the ice machine on the non-food contact portion. CA: Non-food contact surfaces shall be thoroughly cleaned and cleaning frequency shall be enough to prevent accumulation of debris.

17C - physical facilities installed, maintained, and clean

Regulation: 511-6-1.07(5)(a),(b) - good repair, physical facilities maintained; cleaning, frequency & restrictions, cleaned often enough to keep them clean (c)

1 ptsCorrected: NoRepeat: Yes

Observed accumulation of debris and grease on floors and walls. CA: Facility shall be thoroughly cleaned and cleaning frequency shall be enough to prevent accumulation.

17D - adequate ventilation and lighting; designated areas used

Regulation: 511-6-1.07(2)(i) - light bulbs, protective shielding (c)

1 ptsCorrected: NoRepeat: No

Observed that the light shielding on several lights were broken. CA: Light shielding shall appropriatecly protect light bulbs and prevent contamination.

17D - adequate ventilation and lighting; designated areas used

Regulation: 511-6-1.07(4)(b) - designated areas for employee activity, located to prevent contamination of food, equipment, utensils, linens, & single service articles (c)

1 ptsCorrected: YesRepeat: No

Observed employee belongings stored with and above food and food contact surfaces. COS. All items moved. CA: Employee belongings and activities shall be in designated locations that prevent contamination of food and food contact surfaces.

Jan 3, 2025

Routine

Score: 876 violations

2-2D - adequate handwashing facilities supplied & accessible

Regulation: 511-6-1.07(3)(b) - hand drying provision (pf)

4 ptsCorrected: YesRepeat: No

Observed that the hand sink in the front food service area did not have hand drying provisions. COS. Paper towels placed at sink. CA: Hand sinks shall have hand drying provisions.

12C - wiping cloths: properly used and stored

Regulation: 511-6-1.04(4)(m) - wiping cloths, use limitation (c)

3 ptsCorrected: NoRepeat: No

Observed wet wiping cloths stored in sanitizer not at the correct concentration. COS. New sanitizer bucket made. CA: Sanitizer buckets used for storing wiping cloths between uses shall be at the correct concentration.

16A - hot and cold water available; adequate pressure

Regulation: 511-6-1.06(1)(g),(h) - water supply, capacity; pressure (pf)

2 ptsCorrected: NoRepeat: Yes

Observed that the facility is using two tankless hot water units without a storage tank and they have a dishwasher; based on the number of units, the facility is not meeting the peak water demand of the facility. CA: Facility shall have a hot water heater and plumbing system that meets the peak theoretical demand of the facility.

15C - nonfood-contact surfaces clean

Regulation: 511-6-1.05(7)(d) - nonfood-contact surfaces (c)

1 ptsCorrected: NoRepeat: No

Observed mold/mildew like substance on the lid of ice bin; affected area was not in contact with the ice. CA: Non-food contact surfaces shall be clean and cleaning frequency shall be enough to prevent accumulation.

17A - toilet facilities: properly constructed, supplied, cleaned

Regulation: 511-6-1.07(2)(l) - toilet rooms, enclosed (c)

1 ptsCorrected: NoRepeat: Yes

Observed the men's restroom door was not closing all the way. CA: Restroom doors shall be self-closing and tight fitting.

17C - physical facilities installed, maintained, and clean

Regulation: 511-6-1.07(5)(a),(b) - good repair, physical facilities maintained; cleaning, frequency & restrictions, cleaned often enough to keep them clean (c)

1 ptsCorrected: NoRepeat: No

Observed broken tiles throughout the facility. CA: Facility shall be maintained in good repair.

Aug 27, 2024

Routine

Score: 914 violations

2-2B - proper eating, tasting, drinking, or tobacco use

Regulation: 511-6-1.03(5)(k)1&2 - eating, drinking, or using tobacco (c)

4 ptsCorrected: YesRepeat: No

Observed employee drinks in a single-use cup with a lid and straw stored above food contact surfaces. COS> Drinks moved. CA: Employee drinks shall stored and handled to prevent contamination.

16A - hot and cold water available; adequate pressure

Regulation: 511-6-1.06(1)(g),(h) - water supply, capacity; pressure (pf)

2 ptsCorrected: NoRepeat: Yes

Observed that the facility is using two tankless hot water units without a storage tank and they have a dishwasher; based on the number of units, the facility is not meeting the peak water demand of the facility. CA: Facility shall have a hot water heater and plumbing system that meets the peak theoretical demand of the facility.

17A - toilet facilities: properly constructed, supplied, cleaned

Regulation: 511-6-1.07(2)(l) - toilet rooms, enclosed (c)

1 ptsCorrected: NoRepeat: No

Observed the men's restroom door was not closing all the way. CA: Restroom doors shall be self-closing and tight fitting.

17C - physical facilities installed, maintained, and clean

Regulation: 511-6-1.07(5)(a),(b) - good repair, physical facilities maintained; cleaning, frequency & restrictions, cleaned often enough to keep them clean (c)

1 ptsCorrected: NoRepeat: Yes

Observed accumulation of debris on floor throughout facility, especially in the walk-in freezer. CA: Facility shall be thoroughly cleaned and cleaning frequency shall be enough to prevent accumulation.

Mar 1, 2024

Routine

Score: 825 violations

6-1B - proper hot holding temperatures

Regulation: 511-6-1.04(6)(f) - time/temperature control for safety; hot holding (p)

9 ptsCorrected: YesRepeat: No

Observed hot TCS food stored below 135 F (grilled chicken, macaroni, chicken, salmon patty). COS. Items marked with a 4 hour time stamp from when they were cooked. CA: TCS food that uses hot holding as a control for safety shall be held at 135 F or higher.

2-2D - adequate handwashing facilities supplied & accessible

Regulation: 511-6-1.06(2)(o) - using a handwashing sink- operation & maintenance (pf)

4 ptsCorrected: YesRepeat: No

Observed that the hand sink in the back by the 3-compartment sink was blocked by a trashcan and a cart of food. COS. Items moved. CA: Hand sinks shall be kept clear and accessible.

16A - hot and cold water available; adequate pressure

Regulation: 511-6-1.06(1)(g),(h) - water supply, capacity; pressure (pf)

2 ptsCorrected: NoRepeat: No

Observed that the facility is using two tankless hot water units without a storage tank and they have a dishwasher; based on the number of units, the facility is not meeting the peak water demand of the facility. CA: Facility shall have a hot water heater and plumbing system that meets the peak theoretical demand of the facility.

15C - nonfood-contact surfaces clean

Regulation: 511-6-1.05(7)(a)2,3 - equipment, food/nonfood-contact surfaces, and utensils, food-contact surfaces of cooking equipment & nonfood-contact surfaces free of accumulations (c)

1 ptsCorrected: NoRepeat: No

Observed accumulation of debris on and in equipment. CA: Equipment shall be thoroughly cleaned and cleaning frequency shall be enough to prevent accumulation.

17C - physical facilities installed, maintained, and clean

Regulation: 511-6-1.07(5)(a),(b) - good repair, physical facilities maintained; cleaning, frequency & restrictions, cleaned often enough to keep them clean (c)

1 ptsCorrected: NoRepeat: Yes

Observed accumulation of debris on the floors under shelves and equipment, especially on the line, by the 3-compartment sink, and in the walk-in freezer. CA: Facility shall be thoroughly cleaned and cleaning frequency shall be enough to prevent accumulation.

Aug 21, 2023

Routine

Score: 943 violations

12B - personal cleanliness

Regulation: 511-6-1.03(5)(g) - jewelry (c)

3 ptsCorrected: YesRepeat: No

Observed kitchen employees jewelry (bracelets) while preparing food. COS. PIC had employees remove jewelry. CA: With the exception of a plain band ring, no jewelry may be worn on the hands or wrists to include medical information bracelets.

16B - plumbing installed; proper backflow devices

Regulation: 511-6-1.06(2)(r) - system maintained in good repair (p, c)

2 ptsCorrected: NoRepeat: No

Observed that the hand sink in the back by the 3-compartment sink sprayed/exploded when turned on. CA: Plumbing system and fixtures shall be maintained in good repair.

17C - physical facilities installed, maintained, and clean

Regulation: 511-6-1.07(5)(a),(b) - good repair, physical facilities maintained; cleaning, frequency & restrictions, cleaned often enough to keep them clean (c)

1 ptsCorrected: NoRepeat: No

Observed some damaged floor tiles and areas of missing grout; observed accumulation of debris under shelves/equipment and on ceiling tiles. CA:Facility shall be thoroughly cleaned and cleaning frequency shall be enough to prevent accumulation; facility shall be maintained in good repair.