May 19, 2026
Permit/Opening
1600 BLAIRS BRIDGE RD LITHIA SPRINGS, GA 30122
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Re-inspection
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
OBSERVED FLOW METER NOT FUNCTIONING. CA: REPAIR/REPLACE.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
OBSERVED A BROKEN WEIR. CA: REPLACE WEIR.
Routine
Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
OBSERVED GYM GATE NOT WORKING. OBSERVED REAR GATE NOT SELF CLOSING. CA: REPLACE/ING.REPAIR. ALL GATES MUST BE OPERATIONAL AND SELF CLOSING.
Regulation: 511-3-5-.23(5)(f) - (f) broken, unsecured, or missing main drain, or any submerged suction outlet cover/grate
OBSERVED MAIN DRAIN COVER CRACKED AND BROKEN (RIGHT MAIN DRAIN). CA: MAINTAIN ALL VGB COMPLIANT COVERS AND REPLACE BROKEN COVERS.
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
OBSERVED EMERGENCY PHONE NOT OPERATIONAL. CA: REPAIR PHONE.
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
OBSERVED PH AT 7.0. CA: MAINTAIN PH BETWEEN 7.2-7.8. IDEAL: 7.4-7.6
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
OBSERVED FLOW METER NOT FUNCTIONING. CA: REPAIR/REPLACE.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
OBSERVED MISSING WEIRS IN SKIMMERS. CA: REPLACE WEIRS.
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
OBSERVED CYA EXCEEDING MAXIMUM. CA: MAINTAIN BETWEEN 0-90PPM
Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.
OBSERVED BOOT CAP MISSING ON LADDER. CA: REPLACE BOOT CAP.
OBSERVED MENS AND LADIES ROOMS NOT STOCKED WELL. OBSERVED MENS ACCESSIBLE STALL NOT FLUSHING. CA: REPAIR/REPLACE.
Re-inspection
Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
OBSERVED GATES PAD LOCKED- NOT ALL COULD SELF CLOSE. CA: ALL GATES MUT BE UNLOCKED AND OPERATIONAL- CONTACT THE FIRE DEPARTMENT TO APPROVE ANY GATE LOCKINGS AS THIS COULD BE A FIRE/EMERGENCY HAZARD.
FACILITY MUST SUBMIT REPORT FROM FIRE DEPARTMENT ONCE CONTACTED TO EHS
Regulation: 511-3-5-.23(5)(f) - (f) broken, unsecured, or missing main drain, or any submerged suction outlet cover/grate
OBSERVED MAIN DRAIN COVER CRACKED AND BROKEN. CA: MAINTAIN ALL VGB COMPLIANT COVERS AND REPLACE BROKEN COVERS.
Regulation: .17((1)(c) - proper disinfectant level
OBSERVED CL AT 0.5. CA: MAINTAIN CL BETWEEN 2-10PPM.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
OBSERVED FLOW METER STUCK. CA: FIX FLOW METER.
Regulation: 511-3-5-.22(11) - (11) if the water test results are not in compliance with dph rule 511-3-5-.17, the operator shall close the pool, record findings, and make the necessary adjustments to the water chemistry to comply with the chapter. the chemicals used and amounts s
CHEMICALS MUST BE RECORDED TWICE DAILY MINIMUM. CA: RECORD CHEMICALS.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
OBSERVED MISSING WEIRS IN SKIMMERS. CA: REPLACE WEIRS.
Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.
OBSERVED GAUGE ON MAIN POOL BROKEN. CA: REPAIR GAUGE.
OBSERVED LIGHTS NOT WORKING ON THE POOL. CA: REPAIR LIGHTS. NO NIGHT SWIMMING.
REPAIR COVER BETWEEN FOUNTAIN AND POOL OBSERVED IN POOR CONDITION.
Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.
OBSERVED NO SOAP IN RESTROOMS. CA: REPLACE SOAP.
Regulation: 511-3-5-.19(1)(e ) - (e) hot and cold water under pressure shall be provided in dressing facility showers.
OBSERVED NO HOT WATER ON PROPERTY. CA: FIX HOT WATER.
Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.
OBSERVED NO INSPECTION REPORT PRESENT IN PUBLIC VIEW. CA: PLACE IN REPORT IN PUBLIC VIEW.
Routine
Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
OBSERVED GATE (NEAR CABANA) NOT SELF CLOSING/LOCKING. CA: FIX GATE.
Regulation: .10(5) - compliant drain cover
OBSERVED DRAIN COVER (NEAR CABANA) NOT VGB COMPLIANT. CA: FIX/REPLACE COVER WITH VGB COMPLIANT COVER.
Regulation: .17((1)(c) - proper disinfectant level
OBSERVED CHLORINE NOT BEING MAINTAINED (TOO LOW). CA: MAINTAIN CHLORINE LEVELS.
OBSERVED PH ABOVE 7.8. CA: MAINTAIN PH LEVELS BETWEEN 7.2 AND 7.8.
Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.
OBSERVED PUMP AT 0PSI. CA: FIX PUMP.
Regulation: 511-3-5-.22(1) - (1) all swimming pools and spas covered by this chapter shall be maintained under the supervision and direction of a properly trained operator who shall be responsible for the sanitation, safety, and proper maintenance of the pool and all related equ
OBSERVED DAILY RECORD KEEPING DATE MARKED FOR 01/2024. CA: MAINTAIN RECORDS.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
OBSERVED FLOW METER STUCK. CA: FIX FLOW METER.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
OBSERVED MISSING WEIRS IN SKIMMERS. CA: REPLACE WEIRS.
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
OBSERVED NO TRAINING CERTIFICATE PRESENT ONSITE. CA: PROVIDE TRAINING CERTIFICATE.
Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.
OBSERVED NO INSPECTION REPORT PRESENT IN PUBLIC VIEW. CA: PLACE IN REPORT IN PUBLIC VIEW.
Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.
OBSERVED NO SOAP OR PAPER TOWELS IN MEN AND WOMEN RESTROOMS. CA: PROVIDE SOAP AND PAPER TOWELS.
Regulation: 511-3-5-.19(1)(f) - (f) floors of the dressing facility shall be free of joints or openings and shall be continuous throughout the areas. floors shall have a slip-resistant surface that shall be relatively smooth to insure thorough cleaning. floor drains shall be provid
OBSERVED WOMENS SHOWER TILES BROKEN. CA: FIX SHOWER TILES.
Re-inspection
OBSERVED FLOW METER STUCK. CA: FIX FLOW METER.
Regulation: 511-3-5-.19(2)(e ) - (e) soap dispensers for providing either liquid or powdered soap shall be provided at each lavatory. the dispenser shall be of all metal or plastic. no glass shall be permitted in these units.
OBSERVED NO SOAP IN MEN AND WOMEN RESTROOMS. CA: PROVIDE SOAP.
Regulation: 511-3-5-.19(2)(k) - (k) fixtures shall be designed so that they may be readily and frequently cleaned and
OBSERVED TOILETS OVERFLOWING IN THE MENS RESTROOM. CA: CLEAN AND FIX TOILETS.
OBSERVED SHOWER IN MENS RESTROOM BROKEN. CA: FIX SHOWER.
Permit/Opening
OBSERVED SIDE GATE (NEAR RESTROOMS- LOWER LEVEL) AND SIDE GATE (NEAR EMERGENCY PHONE) NOT SELF CLOSING/LOCKING. CA: FIX GATES
Regulation: 511-3-5-.23(5)(h) - (h) absence of required lifesaving equipment on the deck or an emergency phone;
OBSERVED BROKEN SHEPPARD'S HOOK. CA: FIX/REPLACE SHEPPARD'S HOOK.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
OBSERVED MISSING WEIRS IN SKIMMERS. CA: REPLACE WEIRS.
Regulation: 511-3-5-.19(2)(n) - (n) sanitary facility fixtures and dressing area fixtures and furniture shall be cleaned and sanitized with an epa-approved product and as needed to provide a clean and sanitary environment.
OBSERVED WOMEN AND MEN RESTROOMS UNCLEAN. CA: MAINTAIN CLEANLINESS.
Permit/Opening