May 14, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Sep 2, 2025

Routine

Score: 852 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

disinfectant level was observed at 0.5 ppm. CA: Maintain approvable levels 2-10ppm . Ideal levels 1-3 ppm.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

pH < 7.0 was observed. CA: maintain levels 7.2-7.8. Ideal is 704-706

May 13, 2025

Permit/Opening

Score: 952 violations

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

OBSERVED MISSING WEIR NEAR EMERGENCY PHONE. CA: REPLACE WEIR.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(e ) - (e) soap dispensers for providing either liquid or powdered soap shall be provided at each lavatory. the dispenser shall be of all metal or plastic. no glass shall be permitted in these units.

1 ptsCorrected: NoRepeat: No

OBSERVED NO SOAP IN MENS RESTROOM. CA: STOCK WITH SOAP.

Aug 8, 2024

Routine

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

OBSERVED CYA ABOVE 90 PPM. CA: MAINTAIN BETWEEN 0-90PPM.

May 15, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 28, 2023

Permit/Opening

Score: 708 violations

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Disinfectant level was observed at 30 ppm. CA: Maintain approvable levels 1-10ppm . Ideal levels 1-3 ppm.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

pH < 6.8 was observed. CA: maintain levels 7.2-7.8. Ideal is 704-706

14 - vacuum line protected

Regulation: 511-3-5-.10(7) - (7) the vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current iampo sps 4- special use suction fitting for swimming pools, spas and hot tubs.

5 ptsCorrected: NoRepeat: No

Observed vacuum line cover missing. CA: Replace vacuum line cover.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed weirs were missing in Skimmers. CA: Replace weirs.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.

2 ptsCorrected: NoRepeat: No

Observed AstroTurf within 4' of the pool. Deck shall be constructed with a uniform and easily cleanable surface such as concrete, tile, manufactured or acrylic surfaces. CA: remove AstroTurf with in 4 feet of the pool.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Pool sign hanging is lacking some rules- pool rule sign in the bathroom hallway on the ground is complete. CA: hang pool rule sign.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.

1 ptsCorrected: NoRepeat: No

Observed no soap in restrooms and commodes and urinals not cleaned and flushed. CA: Clean and stock restroom.

30 - deck/rinse shower maintained

Regulation: 511-3-5-.18(17) - (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.

1 ptsCorrected: NoRepeat: No

Deck shower not observed to be Functional. CA: Repair deck shower.