DOUGLASVILLE, Douglas County

RIVERWALK HOA-MAIN

7605 RIVER WALK DR DOUGLASVILLE, GA 30135

Pool
Latest score
95
May 21, 2026
City
DOUGLASVILLE
County
Douglas
Inspections
9

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 21, 2026

Permit/Opening

Score: 952 violations

32 - operator training certification available onsite and approved

4 ptsCorrected: NoRepeat: No

OBSERVED NO OPERATOR TRAINING CERTIFICATION AVAILABLE AND APPROVED CA:The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority.

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

OSERVED NO PUBCLIC DISPLAY OF THE INSPECTION REPORT CA: The operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority

May 19, 2026

Permit/Opening

Score: 803 violations

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

OBSERVED THE GATE WONT OPEN FROM THE INSIDE ON PUSH OF THE EXIT BUTTON CA:Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates

32 - operator training certification available onsite and approved

4 ptsCorrected: NoRepeat: No

OBSERVED NO OPERATOR TRAINING CERTIFICATION AVAILABLE AND APPROVED CA:The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority.

34 - inspection report placed in public view

Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.

1 ptsCorrected: NoRepeat: No

OSERVED NO PUBCLIC DISPLAY OF THE INSPECTION REPORT CA: The operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority

May 12, 2026

Permit/Opening

Score: 677 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

OBSERVED THE GATE WONT OPEN FROM THE INSIDE ON PUSH OF THE EXIT BUTTON CA:Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

FLOWMETER OBSERVED NOT WORKING. CA: A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

OBSERVED MISSING WEIRS. CA:Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

OBSERVED NON-FUNCTIONAL GAUGES : CA: A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

BSERVED NO OPERATOR TRAINING CERTIFICATION AVAILABLE AND APPROVED CA:The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

OBSERVED A LADDER MISSING BOOT CAPS CA:Provide a BOOT RUBBER CAPS cover on the LADDER .

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

OBSERVED THE DOOR TO THE PUMP ROOM IN POOR STATE CA: THE DOOR TO BE REPAIRED TO A GOOD STATE OF MAINTAINANCE

Aug 26, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 21, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

May 12, 2025

Re-inspection

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

EMERGENCY PHONE NOT OPERATIONAL. CA: REPAIR THE PHONE.

May 11, 2025

Permit/Opening

Score: 754 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

EMERGENCY PHONE NOT OPERATIONAL.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

FLOWMETER OBSERVED NOT WORKING. CA: REPAIR/ REPLACE FLOWMETER WITH APPROPIATE SIZED ONE.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

OBSERVED MISSING WEIRS. CA: REPLACE WEIRS.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(k) - (k) fixtures shall be designed so that they may be readily and frequently cleaned and

1 ptsCorrected: NoRepeat: No

CLEAN RESTROOM - OBSERVED DIRTY.

May 13, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 23, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.