Jun 4, 2026
Permit/Opening
10 - pump: approved, maintained and operating
observed pump has been removed. had earlier plans for the Pool is to be remodeled and were notified to turn in please turn in plans. . currently notified they will be doing away with the kids pool
28 - flow meter: appropriate range and location
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
observed FO FLOW METER FOR THE KIDS POOL CA: A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.
36 - daily recordkeeping: water testing and self inspection performed
OBSERVED NO DAILY RECORD KEEPING CA: ENHANCE DAILY RECORD KEEPING
26 - gauge(s) in proper location; sight glass installed
Regulation: 511-3-5-.09(9)(b) - (b) the pressure gauge shall be installed downstream from the pump, on the face piping ahead of the filter or on top of the filter in the area of greatest filter pressure.
OBSERVED NO GAUDES FOR THE KIDS POOL CA: The pressure gauge shall be installed downstream from the pump, on the face piping ahead of the filter or on top of the filter in the area of greatest filter pressure.
32 - operator training certification available onsite and approved
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
observed no trainers available onsite ca: The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority.
24 - piping identified and marked
Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.
OBSERED NO PIPING IDENTIFIED AND MARKED ca :All piping shall be marked with directional arrows as necessary to determine flow direction. All piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.
34 - inspection report placed in public view
OBSERVED NO DISPLAY OF INSPECTION REPORT CA: DISPLAY THE INSPECTION REPORT