North Decatur, DeKalb County

RESERVE DECATUR

2600 MILSCOTT DR DECATUR, GA 30033

Pool
Latest score
95
Mar 4, 2026
City
North Decatur
County
DeKalb
Inspections
4

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Mar 4, 2026

Re-inspection

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed a flow meter in disrepair. 13-190(a)(7): An adequately sized flow meter shall be installed on the return line to accurately indicate the circulation rate in gallons per minute (GPM);

Discussed with CPO to replace the flow meter as soon as possible and provide a photo proof via email.

Dec 1, 2025

Routine

Score: 912 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: Yes

Observed low turnover rate of 85gpm (145,00 gal pool should at least have a turnover rate of 402gpm)

13-190(a): The equipment shall operate continuously on a 24 hour basis for a turnover of at least 6 times per day. Flow meter did not meet these standards.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

Observed CYA exceed the max allowed concentration of 100ppm. CYA read 270ppm at time of inspection.

13-189 (c-2): No stabilizing chemicals shall be utilized in any indoor pool. When cyanuric acid is used as a stabilizing agent, the maximum concentration shall not exceed one hundred parts per million (100 p.p.m.)

Discussed with CPO to drain the pool so CYA goes back to normal range. Until violation is resolved the pool must be closed until re-inspection.

May 16, 2025

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

Observed low turnover rate of 150gpm (145,00 gal pool should at least have a turnover rate of 402gpm)

13-190(a): The equipment shall operate continuously on a 24 hour basis for a turnover of at least 6 times per day. Flow meter did not meet these standards.

Jul 30, 2024

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) The equipment shall operate continuously on a 24 hour basis for a turnover of at least 6 times per day. Flow meter did not meet these standards.