May 29, 2026
Permit/Opening
6 - proper disinfectant level
Observed low chlorine concentration levels at 1.35ppm
13-189(c)(1):A free-chlorine residual shall be maintained at a concentration of no less than three parts per million (3ppm) at all times.
Discussed with PIC to reschedule once the chemistry is adjusted.
19 - adequate turnover rate
Observed low turnover rate of 150gpm (Must be at least 180gpm in 65,000gal pool).
13-190(a):The equipment shall be operated continuously on a twenty-four (24) hour basis to obtain the minimum required number of four (4) turnovers per day, or one turnover every six (6) hours (pools); every 30 mins. for spas.