Sep 12, 2025
Re-inspection
3995 FREY RD NW KENNESAW, GA 30144-6700
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Re-inspection
Routine
chlorine observed at 20+ppm, maintain between 2-10ppm
pH observed less than 7 maintain between 7.2-7.8
skimmers not pulling
Permit/Opening
Re-inspection
Re-inspection
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Phone was not working upon inspection, AT&T outage was found to be the cause.
Routine
Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin
chlorine observed at 15.5ppm, maintain between 3-10ppm
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
pH observed greater than 8, maintain between 7.2-7.8
Permit/Opening
Permit/Opening
Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
Observed 2 access gates one by Frey Rd and one by pump room were not self closing as required. CA: Operator to secure gates with an alternative closure until gates are repaired.vAccess gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self latching device is located less than fifty-four inches from the bottom of the gate, 1. The release mechanism shall be located on the pool side of the gate at least three inches below the top of the gate and 2. Any openings in the gate or barrier located within eighteen inches of the release mechanism shall be less than one-half inch. 3. Mechanisms controlled by an access card reader, key entry device or keypad shall be located on the outside of the access gate.
Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch
No line is attached to the life ring. CA: A minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inches or a similar flotation device which is U.S. Coast Guard approved.
Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
No water testing records were available during inspection. CA: Pool water must be tested 2X per day and records maintained.
Regulation: 511-3-5-.10(1)(a) - (a) pools shall use wall or floor inlets that are adequate in design, number and location to provide adequate mixing.
Several return inlet covers are missing. CA: Replace/repair inlet covers.
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
No CPO training certificate was available on site. CA: Obtain and post CPO certificate.
The light is partially out of its receptacle at the side of the spa. CA: Secure/repair light.