May 21, 2026
Re-inspection
28 - flow meter: appropriate range and location
Observed stuck flow meter.
C/A: flow meter needs to be fixed or replaced.
3453 BUSBEE PKWY NW KENNESAW, GA 30144-5595
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Re-inspection
Observed stuck flow meter.
C/A: flow meter needs to be fixed or replaced.
Routine
Regulation: .17((1)(c) - proper disinfectant level
Chlorine test at 0ppm
C/A: chlorine must be between 2-10ppm
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
pH tested at <7.0
C/A: pH must be between 7.2-7.8
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed stuck flow meter.
C/A: flow meter needs to be fixed or replaced.
Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
No record log for the spa was available.
C/A: a record log must be maintained for pools and spas.
Re-inspection
skimmers not pulling/missing weirs
Re-inspection
chlorine observed at 0ppm, maintain between 2-10ppm
skimmers not pulling/missing weirs
Routine
chlorine observed at 0ppm, maintain between 3-10ppm
skimmers not pulling/missing weirs