FOREST PARK, Clayton County

Wyndham Hills Apts

100 MORROW RD FOREST PARK, GA 30297

Pool
Latest score
97
Jun 1, 2026
City
FOREST PARK
County
Clayton
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 1, 2026

Permit/Opening

Score: 972 violations

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo

2 ptsCorrected: NoRepeat: No

Observed multiple missing tiles above pool shell. Pool tiles shall be maintained in good condition. Tiles shall be replaced prior to 2027 pool season.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

observed pitting in pool shell in multiple areas. A plan of written documentation/ plan of correction shall be submitted health department prior to end of 2026 pool season. If not submitted pool will not be permitted in 2027 or until pool has been resurfaced.

May 22, 2025

Permit/Opening

Score: 961 violation

13 - float line in position

Regulation: 511-3-5-.18(2) - (2) rope and float line. a rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of

4 ptsCorrected: YesRepeat: No

Observed no float line in the pool. Cos- float line was added

Aug 21, 2024

Routine

Score: 747 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed entry not self-closing, self-latching proper. Advised PIC access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pH reading of 7.0. Advised PIC during operation, the pH is less than the minimum or more than the maximum levels allowed in DPH Rule 511-3-5-.l7.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed turnover of 8.0 hours, at GPM reading of 65. Advised PIC The equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. The turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less. Unless the rate is otherwise specified in subsection (b) below. This system shall be designed to give the proper turnover rate based on the manufacturer's recommended maximum pressure flow of the filter in dirty media condition of the filter, immediately prior to cleaning the filter.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: Yes

Observed one loose grab rail and no end caps on railing at time of inspection. Advised PIC

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: Yes

Observed peak occupancy signage not filled out at time of inspection. Advised PIC A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.

1 ptsCorrected: NoRepeat: No

Observed no soap and paper towels at men's and women's restroom. Advised PIC Soap, paper towels, and toilet tissue shall be provided in all dispensers.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed no inspection report or operational permit posted. Advised PIC most current permit and inspection report shall be made public.

Apr 8, 2024

Permit/Opening

Score: 914 violations

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed multiple missing weirs (3) at time of inspection. Advised PIC Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed no end caps on railing at time of inspection.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: Yes

Observed peak occupancy signage not filled out at time of inspection. Advised PIC A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

30 - deck/rinse shower maintained

Regulation: 511-3-5-.18(17) - (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.

1 ptsCorrected: NoRepeat: No

Observed decking shower in disrepair at time of inspection. Advised PIC A minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. Water used for rinse showers may be at ambient temperature.

Jun 20, 2023

Re-inspection

Score: 981 violation

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Need peak occupancy sign.

Jun 1, 2023

Permit/Opening

Score: 853 violations

3 - compliant drain covers secure, present and no cracks

Regulation: .10(5) - compliant drain cover

15 ptsCorrected: NoRepeat: No

Single main drain pool. Must have SVRS.

10 - pump: approved, maintained and operating

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

Pool was getting 11.63 hour turnover rate. Advised PIC to increase flow and must adjust to minimum of 8 hour.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

Throw rope for ring buoy insufficient length. Advised PIC to obtain 50 foot or width and 1/2 of pool.