Woodstock, Cherokee County

L.A. Fitness

2060 EAGLE DR WOODSTOCK, GA 30189

Pool
Latest score
80
Jun 8, 2026
City
Woodstock
County
Cherokee
Inspections
9

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 8, 2026

Re-inspection

Score: 802 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: Yes

Observed both gates not properly self-latching. Men's gate does not properly latch every time and women's gate only latches if door is pulled at a certain distance (only latches if door is pulled far but does not latch when door is closed at a shorter distance)

Pool gates must be self-closing/self-latching at every use.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: Yes

Observed flow meter reading around 40 GPM. The second flow meter for this pool was not working. The turn over rate for this pool is 195 GPM. Same issue was observed last year. Must fix.

May 21, 2026

Permit/Opening

Score: 803 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed self-latch mechanism missing from men's entrance into the pool and the gate on the women's side not self-latching. Pool gates must be self-closing/self-latching.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone is not dialing to 911. When phone is picked up, it rings but no one from 911 answers. Attempted 4 times.

An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: Yes

Observed flow meter reading around 40 GPM. The second flow meter for this pool was not working. The turn over rate for this pool is 195 GPM. Same issue was observed last year. Must fix.

Aug 14, 2025

Routine

Score: 951 violation

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Turnover observed at 110 GPM. Must be 192 GPM.

Jun 10, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Sep 5, 2024

Routine

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter not operational - repair or replace

Mar 12, 2024

Re-inspection

Score: 991 violation

31 - dressing showers: clean, maintained, hot and cold water available

Regulation: 511-3-5-.19(1)(f) - (f) floors of the dressing facility shall be free of joints or openings and shall be continuous throughout the areas. floors shall have a slip-resistant surface that shall be relatively smooth to insure thorough cleaning. floor drains shall be provid

1 ptsCorrected: NoRepeat: No

Showers must cleaned thoroughly. Replace the missing tile in the handicap shower.

Mar 11, 2024

Routine

Score: 753 violations

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed no chlorine in the pool. Must be between 0 and 10ppm.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type

5 ptsCorrected: NoRepeat: No

Observed low turn over rate. Must be 192 gpm

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: Yes

Must check pH and chlorine twice a day and tthe logs must be maintained onsite.

Nov 28, 2023

Re-inspection

Score: 951 violation

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Must check pH and chlorine twice a day and the logs must be maintained onsite.

Nov 27, 2023

Routine

Score: 705 violations

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

No chlorine in the pool.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Must check pH and chlorine twice a day.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Missing weirs in few skimmers.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

CPO not maintaining the logs. Must check everything twice a week.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Must post " pool risks", " Risk of drowning" and "Adults must supervise children closely".