Apr 2, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 6, 2025

Routine

Score: 952 violations

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

No weirs observed in any skimmers. Each skimmer must have an automatic adjusting weir per DPH Rule 511-3-5-.11(3)(d). Must install weirs.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Pool and skimmer baskets contained debris at time of inspection. Skimmer baskets and pump strainers must be kept clean to ensure proper circulation and filtration.

Apr 15, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 20, 2024

Routine

Score: 912 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type

5 ptsCorrected: NoRepeat: No

Observed a turnover rate of 260 gpm. The required turnover rate is 293 gpm. Health authority recommended backwashing.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed no weirs in any of the skimmers. Must install weirs.

Apr 16, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 26, 2023

Routine

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter is stuck. Turnover rate could not be assessed.