CANTON, Cherokee County

Smithwyck

1011 SMITHWYCK DR CANTON, GA 30115

Pool
Latest score
99
Apr 29, 2026
City
CANTON
County
Cherokee
Inspections
11

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 29, 2026

Permit/Opening

Score: 992 violations

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed no baby changing stations. Baby changing stations must be provided in both bathrooms

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Must fix the water fountain before opening the pool.

Aug 14, 2025

Re-inspection

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed the cyanuric acid (CYA) level around 100 ppm. Corrective action: lower CYA level to 90 maximum, ideal range is 30-50 ppm.

511-3-5-.17(4) - (4) Stabilizer (if used) Cyanuric acid,ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: - May reduce chlorine efficacy Too Low: - Chlorine Residual rapidly destroyed by sunlight Note: Stabilizer is not needed in indoor or br (4) Stabilizer (if used) Cyanuric acid,ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: - May reduce chlorine efficacy Too Low: - Chlorine Residual rapidly destroyed by sunlight Note: Stabilizer is not needed in indoor or brominated pools and spas.

Aug 7, 2025

Re-inspection

Score: 688 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Front gate is not self-closing/self-latching. Must fix.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone is not working. There is no dial tone. Must fix.

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: Yes

Free chlorine is at 19.5 ppm. Must be between 2-10ppm.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Flow meter is reading around 60 gpm. The turnover rate for pool is 76 gpm.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: Yes

Observed no logs for daily chemical testing onsite.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

Observed no CPO logs onsite as required. Logs on clipboard were all blank.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Hand rails are very loose. Must tighten.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.

1 ptsCorrected: NoRepeat: No

Observed no soap in men’s restroom. Must supply with soap.

Aug 6, 2025

Routine

Score: 755 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Free chlorine measured at 24.5 ppm. Must be between 2.0–10.0 ppm when using stabilized chlorine. Immediate closure required per DPH Rule 511-3-5-.17(1)(c).

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

No documentation was available. Trained operator must document visits and perform a minimum of two visits per week per DPH Rule

32 - operator training certification available onsite and approved

4 ptsCorrected: NoRepeat: No

Observed CPO certificate not available on site. Must keep copy of certificate on site.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed no baby changing stations. Baby changing stations must be provided in both bathrooms

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Does not say pool phone. 911 operator stated the facility will need to get in contact with VOIP to get it sorted out.

May 26, 2025

Re-inspection

Score: 933 violations

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

Observed CPO certificate not available on site. Must keep copy of certificate on site.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: Yes

Observed hand rail above stairs very loose. Must fix.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.

1 ptsCorrected: NoRepeat: Yes

Observed no soap in men’s restroom. Must supply with soap.

May 25, 2025

Re-inspection

Score: 823 violations

1 - barrier: pool enclosed/fencing in compliance

15 ptsCorrected: NoRepeat: No

There is a sizeable opening in fence. Opening is large enough for a small child to squeeze through. There should be no openings in fence.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Hand rail on shallow end is extremely loose. Must tighten.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(e ) - (e) soap dispensers for providing either liquid or powdered soap shall be provided at each lavatory. the dispenser shall be of all metal or plastic. no glass shall be permitted in these units.

1 ptsCorrected: NoRepeat: No

There is no soap in men's rest room. Must supply.

May 23, 2025

Permit/Opening

Score: 851 violation

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

Observed no life saving buoy. Must have a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inches or a similar flotation device which is U.S. Coast Guard approved.

Aug 6, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 1, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 26, 2023

Re-inspection

Score: 991 violation

34 - inspection report placed in public view

Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.

1 ptsCorrected: NoRepeat: No

Inspection report must be posted in public view.

Jul 26, 2023

Routine

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone is not working. There is a dial tone but when you enter a number, it doesn't go through.