Savannah, Chatham County

The Brice Hotel

601 E BAY ST SAVANNAH, GA 31401

Pool
Latest score
100
May 28, 2026
City
Savannah
County
Chatham
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 28, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Dec 22, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Mar 14, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 6, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 4, 2024

Permit/Opening

Score: 803 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine level to read "Hi" on ColorQ equipment. RCA: Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH to be 8.1. RCA: pH should range from 7.4-7.8

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter apparatus to be stuck on 80 GPM. RCA: A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided.

Jul 21, 2023

Routine

Score: 802 violations

8 - chemical feeder operational and approved

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

Observed chemical feeder not able to feed to pool and maintain proper chlorination.

CA: Will conduct follow up on Tuesday to ensure feeder is working efficiently.

RCA: 511-3-5-.23(5)(c ) - (c) The pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate. (c) The pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed combined chlorine level if 0.79ppm.

RCA: 511-3-5-.17(1) - (1) Disinfectant Levels (a) Free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5. (1) Disinfectant Levels (a) Free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

Jul 20, 2023

Routine

Score: 851 violation

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine level below required 2.0ppm minimum.

RCA: .17((1)(c) - Proper disinfectant level (c) Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0