Savannah, Chatham County

OPUS Student Housing

645 E BROUGHTON ST SAVANNAH, GA 31401

Pool
Latest score
100
Apr 8, 2026
City
Savannah
County
Chatham
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 8, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Apr 3, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Mar 8, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Nov 30, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Nov 9, 2023

Permit/Opening

Score: 794 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Clubhouse door on pool deck does not self close. Main gate for pool does not self close.

RCA: 511-3-5-.18(11)(h) - (h) Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates (h) Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self latching device is located less than fifty-four inches from the bottom of the gate, 1. The release mechanism shall be located on the pool side of the gate at least three inches below the top of the gate and 2. Any openings in the gate or barrier located within eighteen inches of the release mechanism shall be less than one-half inch. 3. Mechanisms controlled by an access card reader, key entry device or keypad shall be located on the outside of the access gate.

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Observed 3 chlorine tablets in skimmer basket.

RCA: An automatic chlorinator must be used for proper disinfectant level of swimming pool and ensure recirculation of disinfectant. .17((1)(c) - Proper disinfectant level (c) Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter not in operation.

RCA: 511-3-5-.07(4)(b) - (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed calcium hardness level of 15ppm.

RCA: Calcium hardness shall maintain 150-1000ppm.