May 6, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Oct 23, 2025

Routine

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid (CYA) level registered at 196 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water, until CYA is below 90 ppm.

May 28, 2025

Permit/Opening

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid level registered at 104 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water.

Sep 23, 2024

Routine

Score: 802 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: YesRepeat: No

At time of inspection, the emergency phone was not operational. CPO contacted management and the phone was fixed during the course of the inspection.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

At time of inspection, the flow rate is lower than required. CPO states he will clean the filters thoroughly and troubleshoot why the flow rate is so low, causing the turnover to be low.

Apr 23, 2024

Permit/Opening

Score: 912 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

At time of inspection, observed the flow meter not functioning. CPO states bid has been submitted to replace all flow meters and gauges, as they are all old.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid level registered at 101 ppm (CYA must be 90 ppm or less). CPO will drain some water and add fresh water to lower CYA.

Jul 26, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.