Kingsland, Camden County

Microtel Inn & Suites

1325 E KING AVE KINGSLAND, GA 31548

Pool
Latest score
99
Mar 9, 2026
City
Kingsland
County
Camden
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Mar 9, 2026

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

At time of inspection, there are several chipped areas in the marcite in the floor of the spa. The spa needs resurfacing.

Jul 14, 2025

Re-inspection

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

At time of inspection, the marcite is chipped in the spa. The spa must be resurfaced.

Jul 10, 2025

Permit/Opening

Score: 716 violations

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

At time of inspection, the free chlorine level is exceeding the maximum (registered at 12.36 ppm; FCL must be 3.00-10.00 in spas). CPO is draining some water and adding some fresh water to lower the FCL level to within range. This issue is due to the lack of a chemical feeder for the spa. CPO will order and replace the chemical feeder.

8 - chemical feeder operational and approved

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

At time of inspection, the chlorine erosion feeder is not connected; at this time, chlorine is being manually added to the spa. A chemical feeder must be installed, to allow continual, adjustable addition of chlorine to spa. CPO will order and replace the chlorine erosion feeder.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

At time of inspection, the flow meter markings are illegible (worn/faded). Replace flow meter.

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(c )1.ii. - (ii) the fitting shall not constitute a hazard to the user.

4 ptsCorrected: NoRepeat: No

At time of inspection, all return inlet covers are missing in the spa. Replace covers to improve circulation and to not pose a hazard to swimmers.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

At time of inspection, the vacuum gauge is not functioning. Repair or replace gauge if system is in-use (remove old, unused equipment/gauges).

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

At time of inspection, the marcite in the spa is chipped. The spa must be resurfaced.

Nov 1, 2024

Re-inspection

Score: 844 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Combined chlorine above 0.4 ppm.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter broken.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Daily inspection not being done.

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

Pipes not clearly marked, label piping with direction and equipment served.

Oct 31, 2024

Routine

Score: 802 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

At time of inspection, the emergency phone is not operational. PIC contacted the owner to troubleshoot the phone.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

At time of inspection, the flow meter is not functioning. CPO will replace the flow meter.

May 30, 2024

Permit/Opening

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

At time of inspection, observed flow meter not functioning. CPO will clean out or replace flow meter.

Jul 27, 2023

Permit/Opening

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter is not working, at time of inspection.