CARTERSVILLE, Bartow County

Baymont North Inn & Suites

11 KENT DR CARTERSVILLE, GA 30121

Pool
Latest score
96
Aug 8, 2025
City
CARTERSVILLE
County
Bartow
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Aug 8, 2025

Re-inspection

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: Yes

Observed cyanuric acid above maximum allowed. CA: Cyanuric acid levels may not exceed 90ppm.

Jul 25, 2025

Re-inspection

Score: 812 violations

4 - water clarity: main drains clearly visible

Regulation: 511-3-5-.07(1)(e ) - (e) water clarity shall be maintained. when standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. when standing at a spa's e

15 ptsCorrected: NoRepeat: No

Observed cloudy water in pool, main drains were not visible. CA: Water clarity shall be maintained. When standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: Yes

Observed cyanuric acid above maximum allowed. CA: Cyanuric acid levels may not exceed 90ppm.

Jul 22, 2025

Routine

Score: 764 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine levels below minimum allowed. CA: Chlorine levels must be between 2-10ppm.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH level below minimum allowed. CA: pH level must be between 7.2-7.8.

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed difference between free chlorine and total chlorine greater than 0.4 ppm. CA: Combined chlorine must be below 0.4ppm.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed cyanuric acid above maximum allowed. CA: Cyanuric acid levels may not exceed 90ppm.

Jun 5, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 16, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

May 15, 2024

Permit/Opening

Score: 803 violations

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine levels above maximum.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed PH at 6.5. CA: Informed PIC that PH must range from 7.2-7.8.

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed difference between free chlorine and total chlorine greater than 0.4 ppm.

May 30, 2023

Permit/Opening

Score: 942 violations

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

No pressure gauge available to indicate system conditions. CA: Notified PIC. PIC will have gauge purchased.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed hand rails near 5ft area that are extremely loose. Screw sticking out of railing CA: Informed PIC that hand rails must be secured to prevent from lifting out. Screw sticking out should be removed or covered.