CARTERSVILLE, Bartow County

Icon Cartersville

50 STONE MILL DR. SE CARTERSVILLE, GA 30121

Pool
Latest score
91
Apr 9, 2026
City
CARTERSVILLE
County
Bartow
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 9, 2026

Permit/Opening

Score: 912 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Combined chlorine level exceed 0.4ppm. CA: CPO should adjust chemical and TDS level to ensure maximum disinfectant effectiveness

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed cyanuric acid exceeding maximum of 90ppm. CA: Cyanuric acid should not exceed 90ppm. CPO should drain some water from the pool and refill

Jul 18, 2025

Re-inspection

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: Yes

Observed cyanuric acid exceeding maximum of 90ppm. CA: Cyanuric acid must not exceed maximum.

Jul 14, 2025

Routine

Score: 658 violations

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Observed free chlorine levels below minimum requirement of 2.00 ppm. CA: Free chlorine parameters are 2.00ppm to 10.0ppm.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pH below minimum parameter requirements. CA: pH must be within parameters of 7.2 to 7.8.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.23(5)(h) - (h) absence of required lifesaving equipment on the deck or an emergency phone;

15 ptsCorrected: NoRepeat: No

Observed the absence of proper life saving equipment (shepherds hook with no pole). CA: Appropriate life saving equipment must be present at all times during pool's operation.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed flow meter nonoperational during routine inspection. CA: Flow meter must be operating in order to calculate proper turn over rates.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter nonoperational during routine inspection. CA: Flow meter must be operating in order to ensure proper turn over rate

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(c )1.ii. - (ii) the fitting shall not constitute a hazard to the user.

4 ptsCorrected: NoRepeat: No

Observed a missing return inlet cover in 5' area of pool floor. CA: Return inlet fittings shall not constitute a hazard to the users.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: Yes

Observed cyanuric acid exceeding maximum of 90ppm. CA: Cyanuric acid must not exceed maximum.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.

2 ptsCorrected: NoRepeat: No

Observed several tables and a chair on pool edge during routine inspection. CA: Pool deck must remain clear and unobstructed 4' from pool edge.

May 29, 2025

Permit/Opening

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed CyA measuring above 90ppm. CA: CPO will lower

May 15, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 14, 2023

Routine

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed cyanuric acid reading "Hi" on color Q test kit. CA: Notified CPO

May 15, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.