CARTERSVILLE, Bartow County

South and 20 Apartments

100 CONFERENCE CENTER DR CARTERSVILLE, GA 30121

Pool
Latest score
95
May 15, 2026
City
CARTERSVILLE
County
Bartow
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 15, 2026

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type

5 ptsCorrected: NoRepeat: No

Observed turnover rate below minimum requirement of 4.0. CA: Turnover rate must meet minimum requirement by pool type.

May 14, 2026

Permit/Opening

Score: 783 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pH values higher than the allowable maximum value (see chemical log). CA: pH values must be within the range of 7.2-7.8.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type

5 ptsCorrected: NoRepeat: No

Observed inadequate turnover rate of 4.81. CA: Turn over rate must reach 4.0.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed no signage for pool hours of operations, peak occupancy, or the physical address for the emergency phone. CA: Signage will be updated

Jun 27, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jun 26, 2025

Routine

Score: 755 violations

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Observed chlorine level below minimum allowed. CA: CPO will raise chlorine level and call EH for a new inspection prior to opening the pool

8 - chemical feeder operational and approved

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

Observed chemical feeder not in operation at time of inspection. CA: Chemical feeder must be operational to ensure proper disinfectant levels

10 - pump: approved, maintained and operating

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

Observed pump not in operation at time of inspection. CA: Pump must be operational to ensure proper disinfectant levels.

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed combined chlorine greater than 0.4ppm. CA: Combined chlorine must not exceed 0.4ppm.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter not reading. CA: Flow meter must be operational to ensure proper turn over.

Jun 3, 2025

Re-inspection

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed cyA level measuring above 90ppm. CA: CPO should lower acid level by draining some water from the pool.

Jun 3, 2025

Permit/Opening

Score: 714 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine level below minimum allowed. CA: CPO will raise chlorine level and call EH for a new inspection prior to opening the pool

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Turnover rate was not able to be calculated due to floe meter not working properly. CA: CPO should repair flow meter and ensure turnover rate is adequate

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter not working properly. CA: CPO should replace flow meter to ensure water is being turned over properly.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed cyA level measuring above 90ppm. CA: CPO should lower acid level by draining some water from the pool.

Apr 16, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.