Re-inspection
107 PRINCETON BLVD ADAIRSVILLE, GA 30103
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Re-inspection
Permit/Opening
Regulation: 511-3-5-.18(10)(a) - (a) a light, strong pole not less than twelve feet long including body hook.
Observed shepherds hook not securely attached to pole. CA: Body hook shall be securely attached to 12' pole.
Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.
Observed no directional arrows to identify water flow. CA: All piping shall be marked with directional arrows as necessary to determine flow direction.
Re-inspection
Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.
Observed combined chlorine level at 2.25ppm. CA: CPO should adjust levels to ensure combined chlorine level does not exceed 0.4ppm to keep disinfectant effective
Routine
Regulation: .17(1)(a)(b) - proper disinfectant level
Observed chlorine level at 0.68ppm. CA: Informed PIC that levels must range from 2.0-10.0ppm. Adjust upward and call for reinspection prior to allowing patrons in the pool
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed PH at 6.9. CA: Informed PIC that PH must range from 7.2 -7.8. Adjust pH upward and call for reinspection before allowing patrons in the pool
Re-inspection
Permit/Opening
Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
Observed gate that did not self latch or close without force. CA: informed CPO gate must be repaired.
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Observed emergency phone not operational. Informed CPO pool must remain closed until phone is operational and EH confirms operation.
Re-inspection
Permit/Opening
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Observed emergency phone not operational. Informed PIC and CPO pool must remain closed until phone is operational and EH confirms operation