Jul 29, 2025

Re-inspection

Score: 912 violations

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

Must record bromine level and pH in logbook twice a day, everyday.

20 - return inlets maintained

4 ptsCorrected: NoRepeat: Yes

Replace missing return covers.

Jul 24, 2025

Routine

Score: 727 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone not working. Repair emergency phone. Post address inside emergency phone housing.

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Disinfectant level low. Minimum concentration is 4.0 ppm bromine and maximum is 8.0 ppm

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

pH a little high. Keep 7.2-7.8

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.23(5)(h) - (h) absence of required lifesaving equipment on the deck or an emergency phone;

15 ptsCorrected: NoRepeat: No

No 1st aid kit in pool area. Keep 1st aid kit accessible in pool area or post sign stating "1st aid kit located at front desk"

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Must record bromine level and pH in logbook twice a day, everyday.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Replace missing skimmer weir.

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(c )1.ii. - (ii) the fitting shall not constitute a hazard to the user.

4 ptsCorrected: NoRepeat: No

Replace missing return inlet eyeballs/covers.

Dec 20, 2023

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Dec 6, 2023

Routine

Score: 6111 violations

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: Yes

Entrance door not self latching and broken, will freely open. Door must be self closing, self latching and lockable

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: Yes

Emergency phone not working.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: Yes

No disinfectant in spa

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

pH too high. Keep 7.2-7.8

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

Flow meter installed in wrong location. must be in proper location downstream from filter & heater and must be installed per manufacturers installation instructions

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: Yes

Daily record keeping log not available. Disinfectant level & ph must be recorded twice a day, everyday

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: Yes

Skimmers missing weir. Replace weirs.

20 - return inlets maintained

4 ptsCorrected: NoRepeat: Yes

Replace missing 'eyeballs' for returns/jets.

32 - operator training certification available onsite and approved

4 ptsCorrected: NoRepeat: No

Operator training certification not available for inspection

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

No thermometer for spa. No First Aid Kit.

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: Yes

Must post most recent inspection report.