MONROE, Walton County

Woodlake Community Association, Inc- (MAIN POOL)

4105 LAKESIDE BLVD MONROE, GA 30655

Pool
Latest score
100
May 8, 2026
City
MONROE
County
Walton
Inspections
9

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 8, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 15, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jul 14, 2025

Routine

Score: 803 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Free Chlorine @ 1.0ppm with a range of 2-10ppm

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

pH @ 7.0 with a range of 7.2-7.8

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Daily records not in pump room

Jul 10, 2025

Re-inspection

Score: 851 violation

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Chlorine level not at 2-10 ppm concentration

May 2, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 7, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 8, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Apr 30, 2024

Permit/Opening

Score: 755 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Free Chlorine observed at 13 with a range of 1-10 PPM

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

pH observed at 8 with a range of 7.2 thru 7.8

10 - pump: approved, maintained and operating

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

Pump #2 inoperable at 0 psi

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Flow rate observed at 115 ppm with a turnover rate of <217 gpm

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter installed does not meet <217 gpm turn over rate. Undersized at 190 gpm

Sep 7, 2023

Routine

Score: 981 violation

16 - pool deck: maintained, unobstructed and clean

2 ptsCorrected: NoRepeat: No

Need to patch/repair damaged Pool floor; plaster/gunite between lanes 1 & 2 at left rear corner. Correct by 2024 Season