Augusta, Richmond County

HILTON GARDEN INN SPA

1065 STEVENS CREEK RD AUGUSTA, GA 30907

Pool
Latest score
100
Jan 16, 2026
City
Augusta
County
Richmond
Inspections
12

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jan 16, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Dec 9, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Aug 8, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jan 17, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jan 8, 2025

Permit/Opening

Score: 812 violations

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Adjust chlorine level (free) to 3.0-10.0 ppm range, with chlorinator.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: .06(3)(e) - markings

4 ptsCorrected: YesRepeat: No

Need "No Diving" at stairs N side (COS).

Dec 31, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Aug 29, 2024

Routine

Score: 851 violation

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: YesRepeat: No

Free chlorine 1.0; chlorinator setting adjusted open; close until tested at 3.0 ppm.

Apr 2, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Nov 7, 2023

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Sep 6, 2023

Routine

Score: 851 violation

10 - pump: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

SRV not working on pump: adjust to shut pump off when main occluded or main drain valve turned off to test.

Jun 28, 2023

Routine

Score: 802 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: Yes

pH 6.8; increase to 7.2-7.8

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

The float was not working.

Jun 5, 2023

Routine

Score: 802 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

pH 8.0; reduce to 7.2-7.8.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Float stuck.