Apr 10, 2026
Permit/Opening
4534 ARMOUR RD COLUMBUS, GA 31904
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Re-inspection
Re-inspection
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
Observed facility's pH level at 8.0. During operation, the pH is less than the minimum or more than the maximum levels allowed in DPH Rule 511-3-5-.l7. pH must be between 7.2 and 7.8.
Routine
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
Observed facility's pH level at 7.0. During operation, the pH is less than the minimum or more than the maximum levels allowed in DPH Rule 511-3-5-.l7. pH must be between 7.2 and 7.8.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter not working. A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.
Observed total alkalinity at 40ppm. Total Alkalinity must be between 60 to 180ppm.
Observed calcium hardness at 110ppm. Calcium hardness must be between 150 to 1000ppm.
Permit/Opening