206 NORTHLAKE DR WARNER ROBINS, GA 31093
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
Permit/Opening
Re-inspection
Observed gate is not automatically closing or latching. Entrance gate must automatically close and latch. This inspection it was observed that the springs are pulling the gate open. Repair gate so it will automatically close and latch.
Observed vacuum release system VRS to be disconnected. All single main drain pools must have an operational VRS. Connect VRS or replace if this one is no longer operational. It was also observed that one of the three suction pipes has been cut and capped. Josh with ASP was called to see if this is the main drain pipe. He was not sure but said he will ask the person who worked on the pool. If the main drain is disabled then the VRS will not be needed.
Free chlorine is high at 16ppm. The allowable range for free chorine is 2ppm-10ppm. Reduce free chlorine to within allowable range.
Observed original life ring in the trash can. The life ring is hollow plastic and holding water inside. I did not observe any markings on the life ring. There is no throw rope attached to the life ring. Replace with a U.S. Coast Guard approved life ring with a rope attached that is 1.5 times the width of the pool. I did not observe a replacement life ring in place during inspection.
Observed international no diving symbols have been put in place but they are all 5-6 feet away from the waters edge. Place the international no diving symbol within 18 inches of the water edge on the deck.
(a) The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers in subsections (3)(a) thru (h) above.
(b) Depth markers on the deck shall be within eighteen inches of the water edge and positioned to be read while standing on the deck facing the water.
Routine
Observed gate is not automatically closing or latching. Entrance gate must automatically close and latch. Repair gate so it will automatically close and latch.
Observed vacuum release system VRS to be disconnected. All single main drain pools must have an operational VRS. Connect VRS or replace if this one is no longer operational.
Observed the pool was so cloudy the main drains were not visible. The main drains/bottom of the pool shall be visible at all times. Clarify the pool so that the bottom of the pool is visible.
Observed several chlorine tablets in a pool skimmer. Chlorine tablets can only be dispensed with a chlorine dispenser. Do not use the skimmer for dispensing chlorine. New chlorine dispenser recently installed seems small. Please call if you need assistance sizing a new chlorine dispenser.
Observed life ring floating in the pool. The life ring is hollow plastic and holding water inside. I did not observe any markings on the life rong. There is no throw rope attached to the life ring. Replace with a U.S. Coast Guard approved life ring with a rope attached that is 1.5 times the width of the pool.
Observed no international no diving symbols. Place the international no diving symbol at each NO DIVING marker.
Permit/Opening
Permit/Opening
Permit/Opening
Regulation: 511-3-5-.23(5)(d) - (d) the water turbidity is such that the suction outlet/main drain cover or a standard white marker tile on the bottom of the deepest portion of the pool cannot be seen.
Observed the pool was so cloudy the main drains were not visible. The main drains/bottom of the pool shall be visible at all times. Have pool maintenance come out and work on balancing chemicals so that the bottom of the pool is visible.
Permit/Opening
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter not moving and stuck on the bottom of the indicator tube.A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications. Replace or fix flow meter.
Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:
Observed no pool risk sign. Pool requires to have a pool risk sign during operation. Pool risk sign guidelines given to person in charge (PIC). Have sign made.
Observed Calcium hardness below the appropriate level. Calcium hardness levels shall be from a low of 150 or a max of 1000 ppm. Balance calcium levels.