Mar 17, 2026
Permit/Opening
21 - cyanuric acid level not exceeding maximum
Observed CYA above 90ppm at the time of this inspection. CA: Lower to 90ppm or less.
123 PEPPERTREE CROSSING AVE BRUNSWICK, GA 31525
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Observed CYA above 90ppm at the time of this inspection. CA: Lower to 90ppm or less.
Routine
Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.
Observed a combined chlorine above 0.4ppm at the time of this inspection. CA: Ensure a combined chlorine reading of 0.4ppm or below.
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Observed CYA above 90ppm at the time of this inspection. CA: Lower to 90ppm or less.
Permit/Opening
Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.
Observed a combined chlorine above 0.4ppm at the time of this inspection. CA: Ensure a combined chlorine reading of 0.4ppm or below.
Routine
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Observed emergency phone not operational at the time of this inspection. Phone unable to produce dial tone or call out to 911. CPO attempted to replace phone on site, but unable to get connection to work CA: Ensure emergency phone is working at all times.
Regulation: 511-3-5-.18(13)(b) - (b) warning signs for spas shall be in clear view of the spa and prominently displayed. signs shall state the spa's address, the location of the nearest telephone with references that emergency telephone numbers are posted at the location. these emer
Observed address sign missing near 911 phone. CA: Ensure signage is placed near phone with address of pool.
Routine
Permit/Opening
Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
Observed spa door (indoor) sticking and not allowing entrance and exit. CA: Repair door to open and close properly.
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Observed call box not able to connect and hear 911 operator at the time of this inspection. CA: Repair
Routine
Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.
Observed a combined chlorine above 0.4ppm at the time of this inspection. CA: Ensure a combined chlorine reading of 0.4ppm or below.