Apr 30, 2026
Routine
723 HIGHLAND PARKWAY ELLIJAY, GA 30540
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Routine
Re-inspection
Routine
Regulation: .17((1)(c) - proper disinfectant level
Chlorine below 1.0ppm. Should be 3 ppm to 5 ppm
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
ph=6.6. Should be 7.2-7.8
Routine
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Flow meter on spa appeared to be 'stuck'. Clean flow meter and ensure it is reading 64 gpm.
Re-inspection
FLOW METER OBSERVED NOT WORKING. PROVIDE WORKING FLOW METER.
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
CPO NOT PROVIDED. PROVIDE BY 10/20/2023.
Routine
Regulation: .17((1)(c) - proper disinfectant level
CHLORINE 21.5 OUT OF RANGE. SHOULD BE 3-5 PPM.
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
PH 8.1. SHOULD BE 7.2-7.8
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
FLOW METER OBSERVED NOT WORKING. PROVIDE WORKING FLOW METER.
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
CYA AT 195. SHOULD BE BETWEEN 30-50.
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
CPO NOT PROVIDED. PROVIDE BY 10/20/2023.