ELLIJAY, Gilmer County

TALONA RIDGE RV PARK (SPA)

723 HIGHLAND PARKWAY ELLIJAY, GA 30540

Pool
Latest score
100
Apr 30, 2026
City
ELLIJAY
County
Gilmer
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 30, 2026

Routine

Score: 1000 violations
No violations recorded for this inspection.

Aug 18, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Aug 15, 2025

Routine

Score: 852 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Chlorine below 1.0ppm. Should be 3 ppm to 5 ppm

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

ph=6.6. Should be 7.2-7.8

Jul 24, 2024

Routine

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter on spa appeared to be 'stuck'. Clean flow meter and ensure it is reading 64 gpm.

Jul 21, 2023

Re-inspection

Score: 912 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

FLOW METER OBSERVED NOT WORKING. PROVIDE WORKING FLOW METER.

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

CPO NOT PROVIDED. PROVIDE BY 10/20/2023.

Jul 21, 2023

Routine

Score: 725 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

CHLORINE 21.5 OUT OF RANGE. SHOULD BE 3-5 PPM.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

PH 8.1. SHOULD BE 7.2-7.8

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

FLOW METER OBSERVED NOT WORKING. PROVIDE WORKING FLOW METER.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

CYA AT 195. SHOULD BE BETWEEN 30-50.

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

CPO NOT PROVIDED. PROVIDE BY 10/20/2023.