Pool
Latest score
85
May 21, 2026
City
South Fulton
County
Fulton
Inspections
2

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 21, 2026

Permit/Opening

Score: 851 violation

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.18(11)(a) - (11) barriers. all outdoor swimming pools and spas shall be enclosed by a barrier to prevent entry to the pool area when the pool is closed. (a) the top of the barrier shall be at least forty eight inches above grade maesured on the side of the bar

15 ptsCorrected: NoRepeat: No

Observed the gate being worked on at the time of my inspection. Gate not secured.

511-3-5-.18(11)(a) - (11) Barriers. All outdoor swimming pools and spas shall be enclosed by a barrier to prevent entry to the pool area when the pool is closed. (a) The top of the barrier shall be at least forty eight inches above grade maesured on the side of the bar (11) Barriers. All outdoor swimming pools and spas shall be enclosed by a barrier to prevent entry to the pool area when the pool is closed. (a) The top of the barrier shall be at least forty eight inches above grade maesured on the side of the barried which faces away from the swiming pool. 1. The maximim vertical clearance between a solid surface and the bottom of the barrier shall be four inches measured on the side of the barrier which faces away from the swimming pool. 2. For non-solid surfaces, the veritical clearance between the bottom of the barrier and the grade shall not exceed two inches for a barrier constructed after adoption of the chapter. 3. Where the top of the pool structure is above grade, the barrier may be at ground level, such as the pool structure. 4. Where the barrier is mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shall be four inches.

Jul 16, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.