760 MT. VERNON ATLANTA, GA 30328
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Regulation: .17((1)(c) - proper disinfectant level
Chlorine observed at 12. Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0. C/A Lower chlorine level to normal range.
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
PH above 7.8. Chemical Values: pH 7.2 7.4-7.6 7.8. C/A: Lower Ph level to normal range 7.2-7.8
Flow meter stuck cannot calculate turn over.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter stuck. A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications. C/A: Replace flow meter.