Mar 17, 2026
Initial
16B - plumbing installed; proper backflow devices
Regulation: 511-6-1.06(2)(r) - system maintained in good repair (p, c)
Observed leaking pipe at cold water handle at hand sink.
511-6-1.06(2)(r) - System Maintained in Good Repair (P, C) (r) System Maintained in Good Repair. A plumbing system shall be repaired according to law; P and maintained in good repair.
CA: Repair within 30 days no later that 59 days.
15A - food and nonfood-contact surfaces cleanable, properly designed, constructed, and used
Regulation: 511-6-1.05(1)(a) - materials, general requirements (p, c)
Observed old reach in freezer in main kitchen. Inside of equipment that are exposed to splash, spillage, or other food soiling that require frequent cleaning are not constructed of corrosion resistant, nonabsorbent, and smooth materials.
CA: Remove or replace old reach in freezer (equipment) within 30 days.
511-6-1.05(1)(a) - Materials, General Requirements (P, C) (1) Materials.
(a) General Requirements. Utensils and food-contact surfaces of equipment shall be made of materials that do not allow the migration of deleterious substances or impart colors, odors, or tastes to food and under normal use conditions, and shall be: P safe P, durable, corrosion-resistant, and nonabsorbent. In addition, materials shall be sufficient in weight and thickness to withstand repeated warewashing and shall be finished to have a smooth, easily cleanable surface. Materials shall be resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
15C - nonfood-contact surfaces clean
Regulation: 511-6-1.05(7)(d) - nonfood-contact surfaces (c)
Observed buildup of soiled material on racks near ice machine.
511-6-1.05(7)(d) - Nonfood-Contact Surfaces (C) (d) Nonfood-Contact Surfaces. Nonfood-contact surfaces of equipment shall be cleaned at a frequency necessary to preclude accumulation of soil residues.
17D - adequate ventilation and lighting; designated areas used
Regulation: 511-6-1.07(2)(i) - light bulbs, protective shielding (c)
Observed light shield hanging from light fixture in the restroom and in the back storage area near the rear door.
511-6-1.07(2)(i) - Light Bulbs, Protective Shielding (C) (i) Light Bulbs, Protective Shielding.
-
Except as specified in paragraph 2 of this subsection, light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service and single-use articles.
-
Shielded, coated, or otherwise shatter-resistant bulbs need not be used in areas used only for storing food in unopened packages, if:
(i) The integrity of the packages cannot be affected by broken glass falling onto them; and
(ii) The packages are capable of being cleaned of debris from broken bulbs before the packages are opened.
- An infrared or other heat lamp shall be protected against breakage by a shield surrounding and extending beyond the bulb so that only the face of the bulb is exposed.
CA: Repair or replace within 30 days.