Oct 7, 2025

Routine

Score: 902 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: Yes

Combined chlorine measured 0.6 ppm. See readings log. Corrective action: The combined chlorine shall measure 0.4 ppm lor less.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: Yes

Flow meters do not appear to be functioning; float not moving. Corrective action: The flow meters shall measure the flow rate at approximately 360 GPM for your pool. Advise PIC to replace the flow meter with an adequate flow meter that can measure 360 GPM; the flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate.

Feb 18, 2025

Routine

Score: 902 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: Yes

Combined chlorine measured 1.0 ppm. See readings log. The combined chlorine shall measure 0.4 ppm lor less.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: Yes

1 of 2 flow meters does not appear to be functioning; float not moving. The flow meter shall measure the flow rate at approximately 360 GPM. Advise PIC to replace the flow meter with an adequate flow meter that can measure up to 360 GPM or greater.

Jun 6, 2024

Routine

Score: 902 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: Yes

Combined chlorine measured 1.0 ppm. See readings log. The combined chlorine shall measure 0.4 ppm lor less.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

The flow meter does not appear to be functioning; float not moving. The flow meter shall measure the flow rate at approximately 360 GPM. Advise PIC to replace the flow meter with an adequate flow meter that can measure up to 360 GPM or greater.

Jun 26, 2023

Re-inspection

Score: 951 violation

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: Yes

Combined chlorine measured 0.8ppm. The combined chlorine shall measure 0.4ppm lor less.

May 19, 2023

Permit/Opening

Score: 824 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Combined chlorine measured 1.8ppm. The combined chlorine shall measure 0.4ppm lor less.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

The flow meter measured the flow rate at 8gpm. The flow meter shall measure the flow rate at approximately 360gpm. COS replace the flow meter will an adequate flow meter that can measure up to 360gpm or greater.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: Yes

No weirs located in skimmers. Advised PIC to replace the weirs in each skimmer.

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(5) - (5) the trained operator must perform a minimum of two visits weekly and be able to provide assistance whenever needed.

4 ptsCorrected: NoRepeat: No

CPO must perform a minimum of 2 weekly visits. Written documentation of the visits must be available.