May 27, 2026
Permit/Opening
90 MATCH POINT WAY ROME, GA 30165
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
Permit/Opening
Permit/Opening
Regulation: .17((1)(c) - proper disinfectant level
Observed chlorine sanitizer at maximum level 9.95 ppm CA: Discussed high Free Chlorine levels with CPO and Manager of hotel. COS: CPO to lower Free Chlorine levels into the ideal range and order new test chemicals. Pool to be rechecked by health dept. before opening pool.
Re-inspection
Routine
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Observed CYA level at 95 ppm CA: discussed level with CPO-CPO was aware of high level and taking steps to correct high level with POOL Store
Observed underwater light not securely fastened to pool wall. CA; discussed light with CPO-Light must be properly repaired/secured to pool wall under water to prevent shocking hazards Pool is voluntarily closed until repaired and re-checked.
Permit/Opening
Routine
Permit/Opening