Peachtree City, Fayette County

Peachtree Club Condominium Association Inc.

600 PEACHTREE CLUB DR PEACHTREE CITY, GA 30269

Pool
Latest score
89
Apr 15, 2026
City
Peachtree City
County
Fayette
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 15, 2026

Permit/Opening

Score: 896 violations

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

There are no tile depth markers. Stencils are used. Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. These must be in compliance prior to permitting 2028.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: .06(3)(e) - markings

4 ptsCorrected: NoRepeat: No

There is no contrasting marking at the edge of each step and bench. : The outer two inches of each step, seat bench, or tanning ledge, shall be marked with slip resistant tiles in a contrasting color.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

A weir is not present in each skimmer. Replace weirs in skimmers. Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

The wording for "No Diving" on the deck does not meet proper requirements as outlined for depth markers and no universal symbol for No Diving is present. The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers in subsections. Depth markers must be permanent and on non-slip tiles, in contrasting color. Must be corrected by permitting 2028.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.11(3)(e) There is no equalizer check valve and float valve assembly present in each skimmer. Each skimmer shall be equipped with a trimmer valve capable of distributing the total flow between individual skimmers.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.04(9)(d) The coping at the waterfall area is in disrepair and jagged. All surfaces that come in contact with the user shall be finished so that they do not constitute a cutting, pinching, puncturing or abrasion hazard under casual contact and intended use. All materials shall be maintained in accordance with manufacturer's instructions.

Apr 24, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 29, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Apr 30, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 13, 2023

Routine

Score: 942 violations

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

Provide records of daily water testing

34 - inspection report placed in public view

Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.

1 ptsCorrected: NoRepeat: No

Post inspection report in public view.