FAYETTEVILLE, Fayette County

Camp Southern Ground Swimming Hole Adult Pool

100 SOUTHERN GROUND PKWY FAYETTEVILLE, GA 30215

Pool
Latest score
91
Apr 23, 2026
City
FAYETTEVILLE
County
Fayette
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 23, 2026

Permit/Opening

Score: 912 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

The turnover is not sufficient for this pool. A minimum of 272 gpm must be turned over to ensure full turnover for the required turnover rate of 6 hours.

13 - float line in position

Regulation: 511-3-5-.18(2) - (2) rope and float line. a rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of

4 ptsCorrected: NoRepeat: No

There is no rope and float line present to mark the shallow end of the pool at the slope to the deep end of the pool. Rope and Float Line. A rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of seven feet or less. The transition point or point of slope change of the pool from the active area to the shallow area and from the shallow area to the deep area and at the points of separation of diving, slide and amusement areas shall be visually set apart with a rope and float line, depth markers and a four inch minimum width row of floor tile, or similar means of a color contrasting with the bottom.

Aug 19, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Apr 28, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 15, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 10, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 31, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.