Fayetteville, Fayette County

Retreat at Towne Crossing

160 BELLE DR FAYETTEVILLE, GA 30214

Pool
Latest score
75
May 5, 2026
City
Fayetteville
County
Fayette
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 5, 2026

Permit/Opening

Score: 755 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.18(11)(b) - (b) openings in the barrier shall not allow passage of a four inch diameter sphere.

15 ptsCorrected: NoRepeat: No

The bottom of the fencing has large gaps that exceed 4 inches. These areas may be filled in with dirt, concrete, low lying shrubbery, or other means to prevent unauthorized or accidental entry. Openings in the barrier shall not allow passage of a four inch diameter sphere. Must be corrected prior to permitting.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

There are no letters indicating “FT” on the depth markers on deck and in pool. Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. Correct prior to permitting season 2028

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

The equalizer line is not properly covered. Protect the equalizer line with the appropriate cover. The skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

The cyanuric acid level exceeds the maximum allowance of 90 ppm. Reduce CYA to get maximum effectiveness of the chlorine. Stabilizer (if used) Cyanuric acid, ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: - May reduce chlorine efficacy Too Low: - Chlorine Residual rapidly destroyed by sunlight Note: Stabilizer is not needed in indoor or brominated pools and spas

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

The No Diving and/or universal symbol for No diving are not present on the deck. The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. Correct prior to permitting 2028.

Mar 14, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 9, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Mar 14, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 24, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 26, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.