Apr 29, 2026
Permit/Opening
15 - depth and no diving markers, step marking; installed and contrasting
The letters on the depth marker do not meet minimum height requirement of 4". Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. Must be corrected prior to permitting season 2028
21 - cyanuric acid level not exceeding maximum
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
The cyanuric acid level exceeds the maximum allowance of 90 ppm. Reduce CYA to get maximum effectiveness of the chlorine. Stabilizer (if used) Cyanuric acid, ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: - May reduce chlorine efficacy Too Low: - Chlorine Residual rapidly destroyed by sunlight Note: Stabilizer is not needed in indoor or brominated pools and spas.
22 - signs: peak occupancy/pool/spa/signs legible and in clearview
Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou
The No Diving marking and universal symbol for No Diving is not permanent in nature on the deck; slip resistant stickers are used- are easily peeled off. The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. These must be in compliance prior to permitting 2028