May 7, 2026
Permit/Opening
28 - flow meter: appropriate range and location
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
OBSERVED A NON-FUNCTIONAL LOW METER CA:Violation Code Reference 511-3-5-.07(4)(b) - (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.
Back to Top Back to Top | This page is being served from: CPDHJWHQ0QCFAA © Copyright 2026 Tyler Technologies All Rights Reserved.
15 - depth and no diving markers, step marking; installed and contrasting
Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.
NO DIVING MARKERS WAS OBSERVED MISSING CA: 511-3-5-.18(3)(h) - (h) Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. (h) Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied.
17 - skimmers/gutters maintained and operable
OBSERVED MISSING WIERS. CA: REPLACE MISSING WIERS.
26 - gauge(s) in proper location; sight glass installed
Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.
OBSERVED ALL THE GAUGES NOT FUNCTIONAL CA: 511-3-5-.07(4)(a) - (a) A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location. (a) A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.
32 - operator training certification available onsite and approved
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
OBSERVED THE OPERATIONAL CERTIFICATE NOT ONSITE CA:511-3-5-.22(2) - (2) The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority. (2) The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority.
37 - other violations of the chapter
OBSERVED MISSING BOOT CAPS CA : BOOT CAPS TO BE OBTAINED and replaced