May 13, 2026
Permit/Opening
29 - toilets & lavatories: clean, maintained, and stocked
Observed men's changing room without baby changing station.
2274 WINDING WOODS DR TUCKER, GA 30084
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Observed men's changing room without baby changing station.
Re-inspection
Re-inspection
pH was at 7.0
Routine
-pH was not in range at 6.9. COS at 7.4 on second reading.
-needed fresh tablets in chlorinator.
-Flow meter needed to be adjusted.
Permit/Opening
Observed men's changing room without a diaper changing station.
Routine
13-189(c)(1): The free chlorine residual in all parts of the pool shall be maintained at a concentration of no less than 3ppm and no more than 10 ppm. Observed free chlorine at 2.07 ppm and again at 5.0 ppm.
Re-inspection
13-198(a): All equipment shall be located in a permanent room or completely enclosed area. Observed equipment located outside of the equipment room and accessible to bathers.
Routine
13-202(g): An operable, hard-wired, weatherproof telephone with direct 911 access or capability installed in a conspicuous location shall be readily available at all times. Observed emergency phone not working.
13-189(c)(1): The free chlorine residual in all parts of the pool shall be maintained at a concentration of no less than 3ppm and no more than 10 ppm. Observed free chlorine at 16 ppm and again at 4.56 ppm.
13-189(c)(1): The pool shall be maintained at all times with a pH level between 7.2-7.8. Observed pH at 6.5.
13-197(a): The water in each pool shall be chemically treated with an approved disinfecting agent. Observed CPO fix chlorinator.
13-184(e)(5): Imminent Health Hazard exists if the sanitary facilities are not functional or maintained in a clean and sanitary condition. Observed unflushed toilets and wet floors in bathrooms.
13-198(a): All equipment shall be located in a permanent room or completely enclosed area. Observed equipment located outside of the equipment room and accessible to bathers.
Permit/Opening
Regulation: 511-3-5-.19(1)(e ) - (e) hot and cold water under pressure shall be provided in dressing facility showers.
(e) Hot and cold water under pressure shall be provided in dressing facility showers. Maintain restroom at all times.
Permit/Opening
13-202(e) - lifeguard training certification available onsite. Lifeguards could not produce their certifications.
13-188(d)(1) - permanent-slip-resistant depth markers on vertical pool wall and on the deck. Observed no depth markers on deck
13-188(d)(2) - "NO DIVING" must be in minimum 2 inch letters. Observed no "NO DIVING" markers on deck. Markers on pool wall not 2 inches
Permit/Opening
13-189(C)(1) - FREE CHLORINE SHALL BE MAINTAINED BETWEEN 3PPM AND 10 PPM AT ALL TIMES. OBSERVED CHLORINE AT 0.45 PPM
13-189(C)(1) - PH MUST BE MAINTAINED BETWEEN 7.2 AND 7.8. OBSERVED PH AT 8.6. CORRECTED TO 7.6
13-184(E)(5) - IMMINENT HEALTH HAZARD IF SANITARY FACILITIES ARE NOT FUNCTIONAL. OBSERVED ONE SINK IN MEN'S BATH NOT WORKING