May 22, 2026
Permit/Opening
5400 MEMORIAL DR STONE MOUNTAIN, GA 30083
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
13-205(b)(1): for an outdoor pool, a turnover rate of one turnover every six (6) hours shall be maintained; note the flow meter reading of 60gpm
13-201(b): a shower with tempered water shall be provided at each pool entrance; observed that facility does not have a deck shower
13-187(c): the current inspection report shall be displayed in a conspicuous location; observed that an older report was posted, but not the current or latest report
13-189(a)(5):All pools shall be kept free from sediment, dirt or debris by frequent brushing and vacuuming of the bottom and sidewalls; observed debris at the bottom of the pool
Re-inspection
13-205(b)(1): turnover shall be one ever six (6) hours for outdoor pools; observe flowmeter reading of 80gpm
Routine
13-189(c)(1): the pool shall be maintained in an alkaline condition at all times with a pH level between 7.2 - 7.8; observed pH level of 6.6 at time of inspection
13-205(b)(1): turnover shall be one ever six (6) hours for outdoor pools; observe flowmeter reading of 80gpm
Permit/Opening
Routine
13-205(b)(1):One turnover every six (6) hours (pools).
13-190(a)(7):An adequately sized flow meter shall be installed on the return line to accurately indicate the circulation rate in gallons per minute (GPM). Observed the flow meter not working and at 0.
13-196(a)(4):Each skimmer shall have a properly designed and operating weir or other departmentally approved means of providing effective skimming. Observed the skimmers were filled with debris.
13-188(h)(1):A minimum of 4' of unobstructed deck is required behind diving boards and platforms as measured from the edge of the platform. Observed a chip on the edge of the pool and is a hazard.
13-201(k):At all times, an adequately supply of liquid soap, toilet paper and paper towels and shall be provided and stored in appropriate dispensers. Observed no paper towels in the men's bathhouse.
13-189(a)(5):All pools shall be kept free from sediment, dirt or debris by frequent brushing and vacuuming of the bottom and sidewalls. Observed debris at the bottom of the pool.
Routine
13-189(c)(1)The pool shall be maintained in an alkaline condition at all times with a ph level between 7.2-7.8. Observed ph level at 7.1 but raised to 7.6.
13-190(a)(7)An adequately sized flow meter shall be installed on the return line to accurately indicate the circulation rate in gpm. Observed at 120 for the flow meter rate but raised the flow rate to 186.
13-189(a)(5)All pools shall be free from sediment, dirt or debris by frequent brushing and vacuuming at the bottom and sidewalls. Observed debris at the bottom and CPO began vacuuming the bottom of the pool.
Permit/Opening