STONE MOUNTAIN, DeKalb County

GOLDEN GATE TOWNHOMES

1 CHATFIELD DR STONE MOUNTAIN, GA 30083

Pool
Latest score
95
May 29, 2026
City
STONE MOUNTAIN
County
DeKalb
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 29, 2026

Permit/Opening

Score: 951 violation

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c)(4): Pool water must be tested 2x a day. CPO only conducts test 3x a week.

Aug 16, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jul 3, 2024

Re-inspection

Score: 852 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) The free chlorine residual in all parts of the pool must be maintained at no less than 3.0 ppm -10.0 ppm. Chlorine tested at .51 ppm.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1) The pool must be maintained in an alkaline condition at all times with pH levels between 7.2-7.8. pH recorded at 6.9.

Jul 1, 2024

Routine

Score: 852 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) The free chlorine residual in all parts of the pool must be maintained at no less than 3.0 ppm -10.0 ppm. Chlorine tested at .04 ppm.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1) The pool must be maintained in an alkaline condition at all times with pH levels between 7.2-7.8. pH recorded at 7.1.

Jun 5, 2024

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) Equipment must operate 24/7 to maintain a minimum of 4 turnovers per day. Flow rate in equipment room not efficient enough to meet these standards.

May 28, 2024

Permit/Opening

Score: 754 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) The free chlorine residual in all parts of the pool must be maintained at no less than 3.0 ppm -10.0 ppm. Chlorine tested at .49 ppm.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: Yes

13-189(c)(1) The pool must be maintained in an alkaline condition at all times with pH levels between 7.2-7.8. pH originally 6.2, was only brought up to 6.3.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) Equipment must operate 24/7 to maintain a minimum of 4 turnovers per day. Flow rate in equipment room not efficient enough to meet these standards.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-202(c) Each pool operator shall maintain and make available for inspection onsite upon request a daily record of operating information, together with other data as may be required for each pool relative to operation of the pool. No logbook present at the pool, physical or digital.

Jun 15, 2023

Routine

Score: 748 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: YesRepeat: No

13-189(c)(1) The pool must be maintained in an alkaline condition at all times with pH levels between 7.2-7.8. Observation: It was corrected to 7.2 from 6.7.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7) An adequately sized flow meter must be installed on the return line to accurately indicate the circulation rate in gallons per minute; shall be conspicuously located. Observation: Flow meter is not on return line. It was located on the line that takes water from the pump to filters. Also, flow meter range must be 1.5x of turnover rate. Their turnover rate is 417. Their flow meter max range is 420.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: YesRepeat: No

13-196(a)(4): Each skimmer must have a properly designed and operating weir or other departmentally approved means of providing effective skimming. Observation: 2/6 skimmers missing weirs. 3/6 of the weirs fell off. CPO was able to fix it.

26 - gauge(s) in proper location; sight glass installed

4 ptsCorrected: NoRepeat: No

13-193(a): Adequately sized in-line backwash sight glass on backwash line. Observation: There is no sight glass for backwash.

32 - operator training certification available onsite and approved

4 ptsCorrected: YesRepeat: No

13-187(c): A copy of the pool operator's certificate shall be conspicuously displayed near the operating permit.

Observation: Leasing office printed out operator training. Posted it in box outside on the wall.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(c)(3): 1 Bathroom with hot water temp of 70-104 degrees shall be provided.

Observation: No hot water in bathroom sink.

34 - inspection report placed in public view

1 ptsCorrected: YesRepeat: No

13-187(c): Current inspection report shall be displayed in a conspicuous place where it is easily readable by the public at all times upon entry into the pool area.

Observation: Leasing office printed out the inspection report and placed it in the box outside on the wall.

37 - other violations of the chapter

1 ptsCorrected: YesRepeat: No

13-202(k): First aid kid must be mounted in a conspicuous location in the pool area OR secured by pool personnel on site knowledgeable of it's whereabouts.

Observation: CPO placed first aid kit placed in conspicuous location on the deck.

CPO placed lid on of bathroom trashcan.

May 23, 2023

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-198(a)- Equipment room shall be keep clean and safe

  • Equipment room had multiple empty chemical container stored on the ground. chemicals must be stored on palate or shelf.