Jun 5, 2025

Permit/Opening

Score: 873 violations

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c)(4): Pool water shall be tested 2x/day. Observed logs with testing 1x/day.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Depth markers in both feet and inches. Observed markers in 1/2 FT.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2): Cyanuric acid levels shall not exceed 100pm. Observed cyanuric levels at 104ppm and 106ppm. *Imminent health hazard present.

May 22, 2025

Permit/Opening

Score: 903 violations

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-189(c)(4): The pool water shall be tested 2x daily. Observed testing on some days, 1x/day.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2): Cyanuric acid levels shall not exceed 100ppm. Observed CYA at 120ppm & 115ppm. Imminent health hazard present. Pool closed.

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

13-187(c): The current inspection report shall be displayed in the pool area. Past inspection report not present.

Jun 24, 2024

Routine

Score: 773 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: YesRepeat: No

13-189(c)(1): Pool shall be maintained with a pH level between 7.2-7.8. Observed: 6.8.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Depth markers shall be indicated in feet and inches. Observed: "31/2 feet."

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-196(a)(4): Skimmers shall have an operating weir. A couple of skimmers are missing weirs.

May 23, 2024

Permit/Opening

Score: 902 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) The equipment shall be operated continuously to obtain a minimum turnover rate of 138gpm, observed turnover rate was 63gpm.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: Yes

13-190(a)(7): Adequately sized flow meter shall be installed. The maximum GPM on flow meter is too small. Observed maximum: 90 GPM. Required GPM: 138.

May 20, 2024

Permit/Opening

Score: 802 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed kingsIII emergency phone not working during time of inspection

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter not measuring adequate turnover rate , should reach 138 observed 120

Jun 28, 2023

Permit/Opening

Score: 942 violations

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) The equipment shall be operated continuously to obtain a minimum turnover rate of 130gpm, observed turnover rate was 110gpm.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(k) First aid kit shall be adequately stocked and equipped to treat 15 people. Kit needs to be replenished.