Dunwoody, DeKalb County

DUNWOODY PINES

4355 GEORGETOWN SQ DUNWOODY, GA 30338

Pool
Latest score
99
Apr 28, 2026
City
Dunwoody
County
DeKalb
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 28, 2026

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

13-198(a) Pumps, disinfection equipment, filters, appurtenances and any other approved equipment shall be located in a permanent room, or completely enclosed area. Observed some of the pool equipment outside the pump room (salt cell) and heater.

Aug 7, 2025

Routine

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(k) Each pol shall be supplied with readily available first aid kit. If not in the immediate pool area, adequate signage shall be posted within the immediate area with a minimum "1" high lettering clearly stating the location of the kit. There were not signage to the first aid kit which is located at the front desk.

May 23, 2025

Permit/Opening

Score: 961 violation

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

13-188(d)(1): Depth listed in "3 1/2 ft" and "4 1/2 ft." Depth must be listed in feet and inches.

Jul 9, 2024

Routine

Score: 863 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: YesRepeat: No

V: 13-205(b)(1) Observed 0-20gpm turnover rate on flowmeter. Code says pool must have one turnover every 6 hours. Observed corrective on site (COS).

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: YesRepeat: No

511-3-5-.07(4)(b) Flowrate must show the visible measurement. Observed flowmeter not in range. Observed corrective on site (COS).

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

V: 13-188(d)(1) Depth listed in "3 1/2 ft" and "4 1/2 ft." Depth must be listed in feet and inches.

May 8, 2024

Permit/Opening

Score: 936 violations

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

13-188(d)(1) Depth listed in 3 1/2 ft. Depth must be listed in feet and inches.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

13-202(m) Pool rules missing some required statements. Bathing load not noted.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

13-198(a) Pool heater not located inside of pump room and easily accessible by the general public. Pool heater MUST be secured with a fence or cage to control access or pool permit will not be issued next pool season.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-190(a)(8) No thermometer present in pool. Pool is heated.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-187(c) Permit, CPO certificate, and emergency action plan not posted and easily accessible in pool area.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(k) No first aid kit available in pool area.

Jul 17, 2023

Routine

Score: 763 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: YesRepeat: No

13-189(c)(1): Code says pH mut be between 7.2-7.8 -First Reading: 7.9 -Second Reading: 7.7 -COS

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): Code says flow meter must be operable -Observed flow meter to be stuck

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

13-188(d)(1): Code says depth markers should be 4 inch black lettering -Observed some lettering to be under 4 inches

Jun 16, 2023

Re-inspection

Score: 953 violations

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

13-188(d)(1) Depth markers must be indicated in ft and inches, not '1/2 ft'.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-190(a)(8) Pools that are heated need a thermometer present in the pool to monitor temperature. Observed that there was no thermometer present.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-198(a) All pool equipment must be located in a completely enclosed area, not accessible to the public. Pool heater and salt cell are located outside of the equipment room and accessible to the public. Please enclose these pieces of equipment with a locked gate or other enclosure.

Jun 5, 2023

Routine

Score: 803 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1): Code says chlorine levels must be within 3.0-10.0 ppm -Observed chlorine levels at 0.89 ppm

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1): Code says pH mut be between 7.2-7.8 -Observed pH at 8.5+

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-202(c): Code says daily records of pool testing should be available -Observed no records