Jul 3, 2025
Permit/Opening
4151 MEMORIAL DR DECATUR, GA 30032
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Permit/Opening
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
511-3-5-.18(10)(c ) - (c)The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available.
Note: A 911 sign or the names and phone numbers of the Health Department, police, fire, ambulance service or rescue unit and CPO shall be posted emergency phone.
#37 The equipment room or enclosure and any storage area used for pool supplies, additional equipment, or chemical shall be kept clean, safe and adequately lighted. Approved overhead protection shall be provided to completely cover the entire equipment room or enclosure.
(b) Ventilation and drainage. Ready access, suitable drainage and ventilation of fresh make-up air must be provided for all equipment rooms. The enclosure must be ventilated with outside air by a chlorine-resistant exhaust fan with vents that are located a maximum of four inches (4") above the floor level, equipped with automatic louvers for cross-flow ventilation located at the top of the enclosure for admitting fresh air, and capable of providing one (1) enclosure air change every three (3) minutes.
The entire enclosure shall have a concrete floor that slopes one-quarter inch per foot (1/4" / 1) to a floor drain connected to a sanitary sewer. A hose bibb with an approved backflow prevention system shall be provided in the equipment room or enclosure.